GeneMind FASTASeq S Next-Generation Sequencing System
Available in stock
Scientific China
Store
Scientific China
StorePeople Also Viewed
-
GeneMind NanaLyzer 96 Nucleic Acid Fragment Analyzer
-
GeneMind GenoScout EM Automated Nucleic Acid Extractor
-
GeneMind MrLH-96 Automated Liquid Handling Workstation
-
GeneMind GenoLab M High-Throughput Sequencing System
-
GeneMind FASTASeq 300 High-Throughput Sequencing System
-
GeneMind SURFSeq 5000 High-Throughput Sequencing System
-
GeneMind SURFSeq Q Ultra-High-Throughput Sequencing System
-
Sunlant Cardiopulmonary Function Marker Reagent Kit (Second Generation)
-
Sunlant Myocardial Marker Reagent Kit
-
Sunlant Bluetooth Intelligent Blood Glucose Sensor
| Weight | about 100 kg |
|---|---|
| Power requirements | ≤ 1000 VA |
| Operating environment | Temperature: 19 ℃ – 30 ℃ |
| Instrument control computer | CPU: Gen Inter(R) Core(TM) i7-13700T |
| Parameter | Description |
Product Enquiry
Description
GeneMind FASTASeq S Next-Generation Sequencing System
Product overview
FASTASeq S is an ultra-high-speed sequencer, the platform delivers results from library preparation to data output in: 2 hours for SE50, 3 hours for SE100, and 6.8 hours for PE150 runs. The FASTASeq S integrates an ultra-high-speed fluid system and a new enzyme reaction system, dramatically accelerating sequencing cycle efficiency. Enhanced by an AI-powered base-calling algorithm, the platform achieves exceptional signal recognition accuracy and speed. Optimized flow cell surface amplification technology further ensures high-quality data output——even with nanogram-level trace samples.
Key features
- Swift: Sample Saving
- Social Responsible
Applications
Genome sequencing, targeted sequencing, transcriptomics, metagenomics, molecular research, and other next-generation sequencing workflows.
Sequencing performance
| Flow cell type | Lane | Throughput (Reads/FC) | Specification | Read Length | Data Output | Q30 | TAT |
|---|---|---|---|---|---|---|---|
| FCL | 1 | 20M | SE100-D | SE50 | 1 Gb | ≥90% | ~2.0 hrs |
| SE100-D | SE100 | 2 Gb | ~3.0 hrs | ||||
| 100 cycles | PE50 | 2 Gb | ~4.0 hrs | ||||
| 300 cycles | PE150 | 6 Gb | ≥90% | ~6.8 hrs | |||
| 400 cycles | SE400 | 8 Gb | ≥80% | ~16 hrs | |||
| FCM | 1 | 40M | SE100-D | SE50 | 2 Gb | ≥90% | ~2.5 hrs |
| SE100-D | SE100 | 4 Gb | ~3.5 hrs | ||||
| 100 cycles | PE50 | 4 Gb | ~4.5 hrs | ||||
| 300 cycles | PE150 | 12 Gb | ≥90% | ~7.5 hrs | |||
| 400 cycles | SE400 | 16 Gb | ≥80% | ~16 hrs | |||
| FCX | 1 | 40M | 600 cycles | PE300 | 24 Gb | ≥85% | ~24 hrs |
| FCH | 1 | 80M | SE100-D | SE50 | 4 Gb | ≥90% | ~3.5 hrs |
| SE100-D | SE100 | 8 Gb | ~4.5 hrs | ||||
| 100 cycles | PE50 | 8 Gb | ~5.5 hrs | ||||
| 300 cycles | PE150 | 24 Gb | ≥90% | ~12 hrs |
Applications and sample capacity
| Application | Read length | Data/sample | FCL – 20M | FCM /FCX – 40M | FCH – 80M |
|---|---|---|---|---|---|
| Metagenomics | |||||
| mNGS (based on probe capture) | SE50 | 0.5 M Reads/sample | 20 | 40 | 80 |
| Microbial WGS | PE150 | 1 Gb/sample | 6 | 12 | 24 |
| 16S amplicon sequencing | PE300 | 50-100K reads/sample | / | 200-400 | / |
| Targeted amplicon sequencing | PE300 | 50-100K reads/sample | / | 200-400 | / |
| Shallow shotgun metagenomics | PE150 | 4M Reads/sample | 5 | 10 | 20 |
| Shortgun metagenomics | PE150 | 20M Reads/sample | 1 | 2 | 4 |
| Pathogen detection | |||||
| Respiratory Pathogen | SE50 | 0.5 M Reads/sample | 20 | 40 | 80 |
| TB-tNGS | PE100 | 2 M Reads/sample | 5 | 10 | 20 |
| Oncology | |||||
| Small Oncology Panel (Tissue) | PE150 | 1 Gb/sample | 6 | 12 | 24 |
| Small Oncology Panel (Plasma) | PE150 | 7Gb/samples | 1 | 2 | 4 |
| Small Oncology Targeted RNA panel | PE150 | 1 Gb/sample | 6 | 12 | 24 |
| Genetics | |||||
| Carrier Screening | PE150 | 1.2Gb/sample | 10 | 20 | 40 |
| WES | PE150 | 12 Gb/sample | 0 | 1 | 2 |
| HLA Typing | PE150 | 0.6 Gb/sample | 20 | 40 | 80 |
| PGT-A | SE100 | 3.5 M reads/sample | 5 | 10 | 20 |
| NIPT | SE100 | 3.5 M reads/sample | 5 | 10 | 20 |
| Transcriptome | |||||
| Bacterial mRNA-Seq | PE150 | 2 Gb/sample | 3 | 6 | 12 |
| Human mRNA-Seq | PE150 | 6 Gb/sample | 1 | 2 | 4 |
| Human Total RNA Seq | PE150 | 10 Gb/sample | 0 | 1 | 2 |
| Bacterial total RNA-Seq | PE150 | 6 Gb/sample | 1 | 2 | 4 |
| Quality control | |||||
| CRISPR amplicon QC (Gene editing) | PE150 | 0.5M reads/sample | 20 | 40 | 80 |
| Off-target panel QC (Gene editing) | PE150 | 5M Reads/sample | 4 | 8 | 16 |
| NGS Library QC | SE100 | 0.1 Gb/sample | 60 | 120 | 240 |
Instrument specifications
| Dimensions (W × D × H) | 626 mm × 580 mm× 575 mm |
|---|---|
| Weight | about 100 kg |
| Power requirements | ≤ 1000 VA |
| 200-240 V~, 50/60 Hz | |
| Operating environment | Temperature: 19 ℃ – 30 ℃ |
| non-condensing:20‒80% relative humidity | |
| Altitude:≤3000 m | |
| Instrument control computer | CPU: Gen Inter(R) Core(TM) i7-13700T |
| Memory: 64 GB | |
| Hard drive: 4 TB | |
| Operating system: Windows 10 |
Additional technical information
| Description of Read Header | |
|---|---|
| Parameter | Description |
| <SN> | Serial number of the instrument. |
| <Barcodescore> | Numbers 0 to 9 are used to evaluate the sequencing quality value of the index sequence. The higher the value, the better the quality. |
| <Flowcell ID> | The ID of the sequence chip. |
| <Lane> | Number of the lane, it can be L00、L01、L02、L03、L04, etc. L00 indicates that all lanes are merged. |
| <FOV> | Coordinate of the FOV. |
| <X> | X-coordinate of the cluster. |
| <Y> | Y-coordinate of the cluster. |
| <read1/2> | Read 1 or Read 2. |
| <N> | Default character. |
| <0> | Default character. |
| <Index> | The sequence of the index, if it is a combination of index1 and index2, it should be concatenated with symbol”+”. |
| Note:@<SN>:<Barcodescore>:<Flowcell ID>:<Lane>:<FOV>:<X>:<Y> <read1/2>:<N>:<0>:<Index> The header identifier is represented by the symbol “@”, while the parameter items are differentiated using the symbol “:”. |
Ordering and configuration
Contact Scientific China for availability, supported configurations, compatible consumables, minimum order quantity, installation requirements, lead time, and a formal quotation for the GeneMind FASTASeq S Next-Generation Sequencing System.
Reviews (0)
0.0
Review this product
Share your thoughts with other customers
Only logged in customers who have purchased this product may leave a review.
Similar Products
-
Sku: FRESHLIANCE-B93BBF4BDE
Thermis Log 1 Temperature Recorder
-
Sku: FRESHLIANCE-7693FCD376
Fresh Tag 1 NFC Temperature Logger
-
-
NewSku: GENEMIND-NANALYZER-96
GeneMind NanaLyzer 96 Nucleic Acid Fragment Analyzer
-
NewSku: GENEMIND-SURFSEQ-5000
GeneMind SURFSeq 5000 High-Throughput Sequencing System
-









































































Reviews
There are no reviews yet.