Drawell M510T-A Multi-parameter Analyzer
Product overview
M510T-A Multi-parameter Analyzer Features of M510T-A Multi-parameter Analyzer Specifications of M510T-A Multi-parameter Analyzer
The Drawell M510T-A Multi-parameter Analyzer supports research, clinical, industrial, education, and quality-control laboratories. Scientific China provides model selection, configuration review, export coordination, and formal quotations.
Key features
- 1-8 points calibration with Standard Recognition.
- Selectable pH buffer groups, including USA, NIST, DIN, GB, MERK, JIS.
- User-defined pH buffer or buffer group is supported.
- Automatic electrode diagnosis with pH slope and offset display.
- 1-6 points calibration.
- Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, ppb, etc.
- Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
- Over 10 methods are built-in, including F – , Cl – , Br – , I – , NO 3 – , BF 4 – , NH 4 + , K + , Na + , Ca 2+ , Cu 2+ , Pb 2+ , Ag + and etc., user-defined method is supported.
- Conductivity
- 1-5 points calibration automatically recognizes the standard solutions.
- Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.
- Temperature compensation type (none, linear, pure water).
- E-301-QC 3 in 1 pH composite electrode
- DJS-1VTC EC electrode
Applications
- Professional laboratory testing or sample-processing workflows
- Routine research and quality-control applications
- Application-specific operation according to the selected model
Technical specifications
| Model | M510T-A | |
|---|---|---|
| Parameters | pH/EC/ISE/Temp. (mV/ORP/pX/Resistivity/TDS/Sal.) | |
| pH | Range | -2.000 to 20.000 pH |
| Resolution | 0.1, 0.01, 0.001pH | |
| Accuracy | ±0.002 pH | |
| Calibration Points | Up to 8 | |
| Standard Customization | Yes | |
| Calibration Reminder | Yes | |
| Standard Recognition | USA, NIST, MERK, JIS, GB and DIN buffers | |
| Slope Limit | Yes | |
| mV/ORP | Range | -2000.00 to 2000.00 mV |
| Resolution | 0.1, 0.01 mV | |
| Accuracy | ±0.1 mV or ±0.03% | |
| EH ORP Mode | Yes | |
| ORP Calibration Points | 1 custom point (relative mV) | |
| pX | Range | -2.000 to 20.000 pX |
| Resolution | 0.1, 0.01, 0.001 pX | |
| Accuracy | ±0.002 pX | |
| Calibration Points | Up to 6 | |
| ISE | Range | 1.000e-9 to 9.999e+9 |
| Units | mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb | |
| Resolution | Up to 4 significant digits | |
| Accuracy | ±0.3% | |
| Calibration Points | Up to 8 | |
| Conductivity | Range | 0.000 μS/cm to 3000 mS/cm |
| Resolution | 0.001 μS/cm minimum,various with range selection | |
| Accuracy | ±0.5% FS | |
| Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
| Calibration Points | Up to 5 | |
| Calibration Reminder | Yes | |
| Standard Recognition | 10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm, 12.88mS/cm | |
| Resistivity | Range | 5.00 Ω·cm~100.0 MΩ·cm |
| Resolution | 0.01 Ω·cm minimum | |
| Accuracy | ±0.5% FS | |
| TDS | Range | 0.000 ppm~1000ppt |
| Resolution | 0.001 ppm minimum, changed with range | |
| Accuracy | ±0.5% FS | |
| Salinity | Range | 0.0~80.0 ppt |
| Resolution | 0.1ppt | |
| Accuracy | ±1ppt | |
| Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
| Unit | ºC, ºF | |
| Resolution | 0.1 | |
| Accuracy | ±0.1ºC | |
| Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked | |
| Temp. Compensation | ATC, MTC | |
| Data management | Data Storage | 1000 Groups |
| GLP Features | Yes | |
| Inputs | pH Electrode | BNC(Q9) |
| DO with Temp. Probe | 4-pin aviation connector | |
| Conductivity with Temp. Probe | 5-pin aviation connector | |
| Outputs | USB | USB 2.0 flash memory device, PC, scanner |
| Display options | Backlight | Yes |
| Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off | |
| IP Rating | IP65 | |
| Date and Time | Yes | |
| General | Power | Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
| Dimensions | 90×255×40 mm | |
| Weight | 500g (1.1 lb) | |
| Dimensions (Carton) | 490×410×220 mm | |
| Weight (Gross) | 5.5 kg |
Ordering and configuration
Final specifications, included accessories, consumables, software, certifications, power requirements, installation, warranty, and regulatory availability depend on the selected model and destination. Contact Scientific China to confirm the suitable configuration, minimum order quantity, price, lead time, documentation, and international delivery terms before purchase.