Drawell DW-TY-9000 Full Spectrum Direct Reading Spectrometer
Available in stock
The Drawell DW-TY-9000 Full Spectrum Direct Reading Spectrometer is a professional analytical laboratory instrument. Review features and technical specifications, then request configuration, MOQ, lead time, warranty, and a formal quotation.
Scientific China
Store| Product Category | Spectrophotometer > Full Spectrum Direct Reading Spectrometer |
|---|
Product Enquiry
Description
Drawell DW-TY-9000 Full Spectrum Direct Reading Spectrometer
Product overview
DW-TY-9000 is a Full Range of Solutions for the Entire Metals Industry. It uses full-digital technology to replace bulky photomultiplier tube (PMT) simulation technology and keep pace with international spectrometer technology. The adoption of a vacuum optical chamber design , full-digital excitation light source , advanced CCD detectors , and high-speed data readout system equips the device with high properties, ultra-low limit of detection (LOD), long-term stability, and repeatability . The analytical precision can meet the requirements of laboratory standards, the analytical data is stable and reliable. Widely used in metallurgy, casting, machinery processing, and other industries incoming and outgoing product quality control.
The Drawell DW-TY-9000 Full Spectrum Direct Reading Spectrometer supports research, pharmaceutical, environmental, food, industrial, and quality-control laboratories. Scientific China provides model selection, configuration review, export coordination, and formal quotations.
Key features
- Par type Paschen-Runge structure full spectrum of the optical system;
- Maximum wavelength range(160~850)nm;
- Multiple high-performance CCD detectors;
- Integration of optical chamber forming, dynamic Romanian archives park installation, resistance to environmental temperature changes;
- Light vacuum chamber designed to ensure the C, S, P, N to achieve the best performance;
- Ray room temperature control, constant temperature of 35℃;
- Direct MgF2 lens optics technology and materials to ensure the best energy C, S, P, N ultraviolet wavelengths.
- Integrated manifold, injection electrode technology;
- Optimization of argon gas circuit design ensures effective cooling station excite and motivate metal dust generated in the process effectively into the filter; the sample excitation is more stable, and greatly reduce the body’s intake of metal dust, help protect the operator health and safety;
- Smaller excitation space, argon gas consumption less;
- Easy to use sample holder;
- With the function of the electrode electrode should sweep, longer service life, easy cleaning electrode;
- 13 mm aperture stimulate a more conducive sample analysis;
- Open sample excitation table can be adapted to a variety of sizes, shapes analyze more samples (with cable);
Applications
- Quantitative or qualitative laboratory analysis
- Research, method development, and routine quality control
- Application-specific testing with suitable accessories and methods
Technical specifications
| Item | Index |
|---|---|
| Detection of substrate | Fe、Al、Cu、Ni、Ti、Co、Zn、Sn、Mg、Pb etc |
| Testing time | According to the sample type, generally about 25s |
| Optical system | The Paschen Runge construction full vaccum type optics system |
| Wavelength coverage | 130~800nm |
| Focal length | 400mm |
| Detector | High-performance CCD Array |
| Electrode | Tungsten material injection electrode |
| Analytical gap | The sample analysis of clearance: 3.4mm |
| Operating temperature | (10~35)℃ |
| Storage temperature | (0~45)℃ |
| Operating humidity | 20%~80% |
| Argon purity requirements | 99.999% |
| Argon gas inlet pressure | 0.5MPa |
| Argon flow | Stimulate the flow around 3.5L/min,Maintain flow around 0.4L/min |
| Stimulate the maximum power | 400VA |
| Type of Lamp-house | New digital adjustable light, high energy precombustion technology(HEPS) |
| Discharge frequency | 100-1000 Hz |
| Discharge current | Maximum 400A |
| Excitation aperture | 13mm |
| Vacuum system | The vacuum automatic control and monitoring software |
| Working power supply | 220V AC, 50/60Hz, single phase power supply for protective grounding |
| Instrument size | 725*865*550(mm) |
| Instrument weight | 80kg |
| Program | Fe-Low alloy | Fe-Cr-Ni steel Cr-Ni | ||
|---|---|---|---|---|
| Elements | Min | Max | Min | Max |
| C | 0.006 | 1.3 | 0.008 | 2.5 |
| Si | 0.01 | 3.9 | 0.09 | 4 |
| Mn | 0.03 | 2.1 | 0.12 | 16 |
| P | 0.002 | 0.12 | 0.003 | 0.3 |
| S | 0.002 | 0.16 | 0.001 | 0.4 |
| Cr | 0.01 | 4.5 | 7.4 | 32 |
| Ni | 0.004 | 4.4 | 0.8 | 48 |
| Mo | 0.004 | 1.3 | 0.08 | 4.2 |
| Al | 0.003 | 1.5 | 0.005 | 1.7 |
| Cu | 0.002 | 0.5 | 0.05 | 4.5 |
| Co | 0.001 | 0.5 | 0.008 | 17 |
| Ti | 0.002 | 1.2 | 0.005 | 1.1 |
| Nb | 0.002 | 0.3 | 0.02 | 2 |
| V | 0.003 | 0.9 | 0.02 | 9.5 |
| W | 0.03 | 2.1 | 0.002 | 4.1 |
| Pb | 0.003 | 0.03 | 0.001 | 0.02 |
| Mg | 0.001 | 0.14 | 0.001 | 0.14 |
| B | 0.006 | 0.02 | 0.007 | 0.02 |
| Sn | 0.001 | 0.09 | 0.003 | 0.05 |
| Zn | 0.002 | 0.04 | 0.006 | 0.08 |
| Sb | 0.002 | 0.02 | 0.0005 | 0.022 |
| Fe | (Remain) | (Remain) |
Ordering and configuration
Final specifications, included accessories, consumables, software, certifications, power requirements, installation, warranty, and regulatory availability depend on the selected model and destination. Contact Scientific China to confirm the suitable configuration, minimum order quantity, price, lead time, documentation, and international delivery terms before purchase.
Reviews (0)
Only logged in customers who have purchased this product may leave a review.































Reviews
There are no reviews yet.