Drawell DW-F96PRO Fluorescence Spectrophotometer
Available in stock
The Drawell DW-F96PRO Fluorescence Spectrophotometer is a professional analytical laboratory instrument. Review features and technical specifications, then request configuration, MOQ, lead time, warranty, and a formal quotation.
Scientific China
Store| Product Category | Spectrophotometer > Fluorescence Spectrophotometer |
|---|
Product Enquiry
Description
Drawell DW-F96PRO Fluorescence Spectrophotometer
Product overview
Fluorescence analysis is a highly sensitive and high selective sophisticated analytical method. This method can provide information including excitation and emission spectrum, emission light intensity and measurement of life of emission light and polarization fluorescence, etc. This method can provide a wide linear range of the working curve. It has become an important analytical method in the region of trace analysis. This method has been used in:
The Drawell DW-F96PRO Fluorescence Spectrophotometer supports research, pharmaceutical, environmental, food, industrial, and quality-control laboratories. Scientific China provides model selection, configuration review, export coordination, and formal quotations.
Key features
- Two operations modes could be chosen: fluorescence intensity and luminous intensity. Fluorescence scanning, kinetic determination, and quantity analysis could be done under fluorescence intensity mode.
- High-performance sensitivity simplifies the measurement of low detective sample: 365nm exciting wavelength, Raman peak of water S/N≥150.
- 10 stages of gain adjustment could be chosen for emission spectrum scanning, including high speed low S/N scanning, and precise scanning. Total spectrum scanning could be done in 1 second. With the intelligent pre-scanning feature, unknown sample spectrum information could be detected rapidly. Auto-omission of the influence of scattering peaks and harmonic peaks ensures the best measurement parameters and locates the fluorescence emission peak.
- Support off-line mode and online mode. Under off-line mode, the instrument’s computer system offers the fluorescence intensity measurement, concentration direct reading, auto 0 adjustment, auto background subtraction and etc. Under online mode, we could use quality and quantity software to control data acquisition and analysis through the USB2.0 interface.
- High stable and long-life 150W xenon lamp and power source ensures high stable testing and a wide range of the spectrum.
- The normalized feature for fluorescence value could make different fluorescence results comparable.
- Provide optional PC qualitative and quantitative software package with expansible time scanning, wavelength scanning, graphic calculation, and storage-access abilities.
- Optional accessories for different measurements, including single hole cell holder, fluorescence sample holder for different features, 200μl micro-scale centrifuge tube, microscale capillary sample holder, semi-auto sample introduction accessories, membrane sample accessories, powder sample accessories, jacket sample accessories and etc.
- Light source:
- Hamamatsu 150W Xenon lamp
- Exciting optical filters:
- Interference optical filter
- a) Standard set is equipped with an interference optical filter of central wavelength at 365nm and 10nm bandwidth.
- b) An optional interference optical filer of 25mm diameter of wavelength of 250-700 nm can be provided on users demand.
Applications
- Quantitative or qualitative laboratory analysis
- Research, method development, and routine quality control
- Application-specific testing with suitable accessories and methods
Technical specifications
| Model | DW-F96PRO |
|---|---|
| Picture | |
| Light source: | Hamamatsu 150W Xenon lamp |
| Exciting optical filters: | Interference optical filter |
| a) Standard set is equipped with an interference optical filter of central wavelength at 365nm and 10nm bandwidth. b) An optional interference optical filer of 25mm diameter of wavelength of 250-700 nm can be provided on users demand. | |
| Emission monochromator: | C-T diffraction grating(Em 200-900nm,bandwidth 10nm) |
| Wavelength accuracy | ±1nm |
| Wavelength repeatability | ≤0.5nm |
| Sensitivity: | Raman peak of water in 1 cm quartz fluorescence cuvette with S/N≥150 |
| Linear measurement(r): | ≥0.995 |
| Stability: | better than 1.5%/10min |
| Response time: | (0.1-4)s 6 stages adjustable |
| Fluorescence display value: | 0.00-600.00 |
| Data transmission: | USB2.0 |
| Power | 220V±22V 50Hz±1Hz 190W |
| Package Dimensions | 380 x440 x240 mm 0.04M 3 |
| G.W. | 14Kg |
| Standard Accessories | |
|---|---|
| 365nm filter(Preassembled) | 1 pc |
| F96PRO software package | 1 set |
| Power cable | 1 pc |
| USB cable | 1 pc |
| Fuse(2A) | 2 pcs |
| Fuse(5A) | 2 pcs |
| Quartz fluorescence sample cell10mm | 1 pair |
| Optional Accessories | |
| 200-700nm interference optical filter (φ25mm) | |
| 10mm quartz fluorescence cell | |
| Printer cable | |
| Dedicated serial interface printer |
Ordering and configuration
Final specifications, included accessories, consumables, software, certifications, power requirements, installation, warranty, and regulatory availability depend on the selected model and destination. Contact Scientific China to confirm the suitable configuration, minimum order quantity, price, lead time, documentation, and international delivery terms before purchase.
Reviews (0)
Only logged in customers who have purchased this product may leave a review.

























Reviews
There are no reviews yet.