Gentier X3 Series Real-Time PCR System
Available in stock
Scientific China
StorePeople Also Viewed
-
SSP-GL01A Automated NGS Library Prep System
-
Automated Nucleic Acid Extraction Workstation SAW-96
-
Automated Nucleic Acid Extraction Workstation SAW-48
-
STC-96A Real-Time PCR System
-
STC-96A PLUS Real-Time PCR System
-
Nucleic Acid Extraction System SSNP-9600A
-
Nucleic Acid Extraction System SSNP-3000A
-
Nucleic Acid Extraction System SMPE-960
-
Nucleic Acid Extraction System SSNP-A6
-
Nucleic Acid Extraction System SSNP-2000B
| Manufacturer | Tianlong |
|---|---|
| Model | Gentier X3E, Gentier X3S, Gentier X3R, Gentier X3C |
| Touch Screen Stand Alone Operation | YES, NO, YES, NO |
| Stand Alone Operation | YES, NO, YES, NO |
| Throughput | 32 х 3, 32 х 3, 32 х 3, 32 х 3 |
| Certificate | CE; CB; RoHS, CE; CB; RoHS, CE; CB; RoHS, CE; CB; RoHS |
| Fluorescence Scanning Time | 2s for 32 wells fluorescence scanning, 2s for 32 wells fluorescence scanning, 2s for 32 wells fluorescence scanning, 2s for 32 wells fluorescence scanning |
| Fluorescence Channels | 6, 6, 4, 4 |
| Dye Compatibility | Channel 1: FAM, SYBR Green I, etc. Channel 2: HEX, TET, VIC, JOE, etc. Channel 3: Texas Red, ROX, etc. Channel 4: Cy5, etc. Channel 5: Alexa Fluor 680, etc. Channel 6: Tamra, Cy3, NED, etc., Channel 1: FAM, SYBR Green I, etc. Channel 2: HEX, TET, VIC, JOE, etc. Channel 3: Texas Red, ROX, etc. Channel 4: Cy5, etc. Channel 5: Alexa Fluor 680, etc. Channel 6: Tamra, Cy3, NED, etc., Channel 1: FAM, SYBR Green I, etc. Channel 2: HEX, TET, VIC, JOE, etc. Channel 3: Texas Red, ROX, etc. Channel 4: Cy5, etc., Channel 1: FAM, SYBR Green I, etc. Channel 2: HEX, TET, VIC, JOE, etc. Channel 3: Texas Red, ROX, etc. Channel 4: Cy5, etc. |
| Heating Rate | Average Heating Rate: ≥ 4.5°C/s ; Max. Heating Rate: ≥6.2°C/s, Average Heating Rate: ≥ 4.5°C/s ; Max. Heating Rate: ≥6.2°C/s, Average Heating Rate: ≥ 4.5°C/s ; Max. Heating Rate: ≥6.2°C/s, Average Heating Rate: ≥ 4.5°C/s ; Max. Heating Rate: ≥6.2°C/s |
| Cooling Rate | Average Cooling Rate: ≥ 3.5°C/s; Max. Cooling Rate: ≥ 5.0°C/s, Average Cooling Rate: ≥ 3.5°C/s; Max. Cooling Rate: ≥ 5.0°C/s, Average Cooling Rate: ≥ 3.5°C/s; Max. Cooling Rate: ≥ 5.0°C/s, Average Cooling Rate: ≥ 3.5°C/s; Max. Cooling Rate: ≥ 5.0°C/s |
| Temperature Accuracy | ≤0.1℃, ≤0.1℃, ≤0.1℃, ≤0.1℃ |
| Temperature Uniformity | ±0.2℃, ±0.2℃, ±0.2℃, ±0.2℃ |
| Temperature Precision | ≤ 0.1°C, ≤ 0.1°C, ≤ 0.1°C, ≤ 0.1°C |
| Repeatability | CV ≤ 1%, CV ≤ 1%, CV ≤ 1%, CV ≤ 1% |
| Linear Correlation | │r│≥ 0.995, │r│≥ 0.995, │r│≥ 0.995, │r│≥ 0.995 |
| Sample Cabin | Three independent sample cabin, Three independent sample cabin, Three independent sample cabin, Three independent sample cabin |
| Lightsource | High-brightness, long-life, maintenance-free LED light source, High-brightness, long-life, maintenance-free LED light source, High-brightness, long-life, maintenance-free LED light source, High-brightness, long-life, maintenance-free LED light source |
| Key Applications | Absolute quantification analysis, relative quantification analysis, melting curve, high resolution melting (HRM), genotyping, end point fluorescence, etc., Absolute quantification analysis, relative quantification analysis, melting curve, high resolution melting (HRM), genotyping, end point fluorescence, etc., Absolute quantification analysis, relative quantification analysis, melting curve, high resolution melting (HRM), genotyping, end point fluorescence, etc., Absolute quantification analysis, relative quantification analysis, melting curve, high resolution melting (HRM), genotyping, end point fluorescence, etc. |
| Special Temperature Protocol | Touchdown step, long step, gradient step, standard step and so on., Touchdown step, long step, gradient step, standard step and so on., Touchdown step, long step, gradient step, standard step and so on., Touchdown step, long step, gradient step, standard step and so on. |
| Data Storage | 1000 results can be stored in machine, 1000 results can be stored in machine, 1000 results can be stored in machine, 1000 results can be stored in machine |
| Power Failure Protection | Automatically start running experiments after power supply, Automatically start running experiments after power supply, Automatically start running experiments after power supply, Automatically start running experiments after power supply |
| Communication Specification | Network Port: TCP/IP protocol; Ethernet connection; USB Port: 2.0;, Network Port: TCP/IP protocol; Ethernet connection; USB Port: 2.0;, Network Port: TCP/IP protocol; Ethernet connection; USB Port: 2.0;, Network Port: TCP/IP protocol; Ethernet connection; USB Port: 2.0; |
| Power Supply and Power Consumption | AC 100~240V;50/60Hz; 1000VA;, AC 100~240V;50/60Hz; 1000VA;, AC 100~240V;50/60Hz; 1000VA;, AC 100~240V;50/60Hz; 1000VA; |
| Suitable Consumables | Conventional 0.2 mL 8-strip PCR tube (clear, white) Tianlong specialized 0.2 mL 8-strip PCR tube (clear, white), Conventional 0.2 mL 8-strip PCR tube (clear, white) Tianlong specialized 0.2 mL 8-strip PCR tube (clear, white), Conventional 0.2 mL 8-strip PCR tube (clear, white) Tianlong specialized 0.2 mL 8-strip PCR tube (clear, white), Conventional 0.2 mL 8-strip PCR tube (clear, white) Tianlong specialized 0.2 mL 8-strip PCR tube (clear, white) |
Product Enquiry
Description
Gentier X3 Series Real-Time PCR System
PCR thermal cycler is the fundamental instrument that provide specific temperature cycling for PCR reactions and facilitate DNA amplification . Tianlong Gentier X3 Series real-time PCR equipment features three independent thermal blocks , supporting users to run a maximum 3×32 well samples in three different protocols simultaneously . This feature can help you save a lot of time and budget . With the powerful and efficient temperature control system, user-friendly operational designs, Tianlong Gentier X3 Series can provide maximal reliability and efficiency for all your real-time PCR needs.
Why choose the Gentier X3 Series Real-Time PCR System?
- Gentier X3 Series is a 3 block PCR machine. It can process a maximum 3×32-well samples in three different protocols at the same time.
- With 6 or 4 fluorescence channels depending on the model, GentierX3 Series can complete 32 wells of fluorescence scanning in one block within 2s, serving as a great boost to the PCR testing efficiency when there is a high throughput need.
- The Gentier X3 Series PCR cycler delivers precise temperature control (≤ 0.1℃) along with a compensation heating function for accurate reactions and uses a hot lid with pressure sensing to prevent consumable deformation and evaporation.
- Gentier X3 Series can offer multiple functions including absolute quantification analysis, relative quantification analysis, melting curve, high resolution melting (HRM), genotyping, endpoint fluorescence, etc.
- The Gentier X3 Series PCR thermal cycler systems feature a 13.3-inch full-color touch screen adjustable for ergonomic viewing, offers standalone and PC control options, and includes power failure protection to automatically resume experiments.
Technical specifications
| Model | Gentier X3E | Gentier X3S | Gentier X3R | Gentier X3C |
|---|---|
| Touch Screen Stand Alone Operation | YES | NO | YES | NO |
| Stand Alone Operation | YES | NO | YES | NO |
| Throughput | 32 х 3 | 32 х 3 | 32 х 3 | 32 х 3 |
| Certificate | CE; CB; RoHS | CE; CB; RoHS | CE; CB; RoHS | CE; CB; RoHS |
| Fluorescence Scanning Time | 2s for 32 wells fluorescence scanning | 2s for 32 wells fluorescence scanning | 2s for 32 wells fluorescence scanning | 2s for 32 wells fluorescence scanning |
| Fluorescence Channels | 6 | 6 | 4 | 4 |
| Dye Compatibility | Channel 1: FAM, SYBR Green I, etc. Channel 2: HEX, TET, VIC, JOE, etc. Channel 3: Texas Red, ROX, etc. Channel 4: Cy5, etc. Channel 5: Alexa Fluor 680, etc. Channel 6: Tamra, Cy3, NED, etc. | Channel 1: FAM, SYBR Green I, etc. Channel 2: HEX, TET, VIC, JOE, etc. Channel 3: Texas Red, ROX, etc. Channel 4: Cy5, etc. Channel 5: Alexa Fluor 680, etc. Channel 6: Tamra, Cy3, NED, etc. | Channel 1: FAM, SYBR Green I, etc. Channel 2: HEX, TET, VIC, JOE, etc. Channel 3: Texas Red, ROX, etc. Channel 4: Cy5, etc. | Channel 1: FAM, SYBR Green I, etc. Channel 2: HEX, TET, VIC, JOE, etc. Channel 3: Texas Red, ROX, etc. Channel 4: Cy5, etc. |
| Heating Rate | Average Heating Rate: ≥ 4.5°C/s ; Max. Heating Rate: ≥6.2°C/s | Average Heating Rate: ≥ 4.5°C/s ; Max. Heating Rate: ≥6.2°C/s | Average Heating Rate: ≥ 4.5°C/s ; Max. Heating Rate: ≥6.2°C/s | Average Heating Rate: ≥ 4.5°C/s ; Max. Heating Rate: ≥6.2°C/s |
| Cooling Rate | Average Cooling Rate: ≥ 3.5°C/s; Max. Cooling Rate: ≥ 5.0°C/s | Average Cooling Rate: ≥ 3.5°C/s; Max. Cooling Rate: ≥ 5.0°C/s | Average Cooling Rate: ≥ 3.5°C/s; Max. Cooling Rate: ≥ 5.0°C/s | Average Cooling Rate: ≥ 3.5°C/s; Max. Cooling Rate: ≥ 5.0°C/s |
| Temperature Accuracy | ≤0.1℃ | ≤0.1℃ | ≤0.1℃ | ≤0.1℃ |
| Temperature Uniformity | ±0.2℃ | ±0.2℃ | ±0.2℃ | ±0.2℃ |
| Temperature Precision | ≤ 0.1°C | ≤ 0.1°C | ≤ 0.1°C | ≤ 0.1°C |
| Repeatability | CV ≤ 1% | CV ≤ 1% | CV ≤ 1% | CV ≤ 1% |
| Linear Correlation | │r│≥ 0.995 | │r│≥ 0.995 | │r│≥ 0.995 | │r│≥ 0.995 |
| Sample Cabin | Three independent sample cabin | Three independent sample cabin | Three independent sample cabin | Three independent sample cabin |
| Lightsource | High-brightness, long-life, maintenance-free LED light source | High-brightness, long-life, maintenance-free LED light source | High-brightness, long-life, maintenance-free LED light source | High-brightness, long-life, maintenance-free LED light source |
| Key Applications | Absolute quantification analysis, relative quantification analysis, melting curve, high resolution melting (HRM), genotyping, end point fluorescence, etc. | Absolute quantification analysis, relative quantification analysis, melting curve, high resolution melting (HRM), genotyping, end point fluorescence, etc. | Absolute quantification analysis, relative quantification analysis, melting curve, high resolution melting (HRM), genotyping, end point fluorescence, etc. | Absolute quantification analysis, relative quantification analysis, melting curve, high resolution melting (HRM), genotyping, end point fluorescence, etc. |
| Special Temperature Protocol | Touchdown step, long step, gradient step, standard step and so on. | Touchdown step, long step, gradient step, standard step and so on. | Touchdown step, long step, gradient step, standard step and so on. | Touchdown step, long step, gradient step, standard step and so on. |
| Data Storage | 1000 results can be stored in machine | 1000 results can be stored in machine | 1000 results can be stored in machine | 1000 results can be stored in machine |
| Power Failure Protection | Automatically start running experiments after power supply | Automatically start running experiments after power supply | Automatically start running experiments after power supply | Automatically start running experiments after power supply |
| Communication Specification | Network Port: TCP/IP protocol; Ethernet connection; USB Port: 2.0; | Network Port: TCP/IP protocol; Ethernet connection; USB Port: 2.0; | Network Port: TCP/IP protocol; Ethernet connection; USB Port: 2.0; | Network Port: TCP/IP protocol; Ethernet connection; USB Port: 2.0; |
| Power Supply and Power Consumption | AC 100~240V;50/60Hz; 1000VA; | AC 100~240V;50/60Hz; 1000VA; | AC 100~240V;50/60Hz; 1000VA; | AC 100~240V;50/60Hz; 1000VA; |
| Suitable Consumables | Conventional 0.2 mL 8-strip PCR tube (clear, white) Tianlong specialized 0.2 mL 8-strip PCR tube (clear, white) | Conventional 0.2 mL 8-strip PCR tube (clear, white) Tianlong specialized 0.2 mL 8-strip PCR tube (clear, white) | Conventional 0.2 mL 8-strip PCR tube (clear, white) Tianlong specialized 0.2 mL 8-strip PCR tube (clear, white) | Conventional 0.2 mL 8-strip PCR tube (clear, white) Tianlong specialized 0.2 mL 8-strip PCR tube (clear, white) |
| Dimension | 380mm(L) × 410mm (W) × 395mm (H) | 380mm(L) × 410mm (W) × 395mm (H) | 380mm(L) × 410mm (W) × 395mm (H) | 380mm(L) × 410mm (W) × 395mm (H) |
| Weight | 34kg | 34kg | 34kg | 34kg |
| Touch Screen | YES | NO | YES | NO |
| Temperature Precision | │r│≥ 0.995 | │r│≥ 0.995 | │r│≥ 0.995 | │r│≥ 0.995 |
| Key Applications | High-brightness, long-life, maintenance-free LED light source | High-brightness, long-life, maintenance-free LED light source | High-brightness, long-life, maintenance-free LED light source | High-brightness, long-life, maintenance-free LED light source |
| 1000 results can be stored in machine | Automatically start running experiments after power supply | Automatically start running experiments after power supply | Automatically start running experiments after power supply | Automatically start running experiments after power supply |
Applications
Suitable for professional laboratories, hospitals, diagnostic centers, research facilities, and other qualified users requiring pcr systems & thermal cyclers.
Request a quotation
Contact Scientific China for configuration guidance, availability, minimum order quantity, shipping options, and a formal quotation.
Brand: Tianlong
Reviews (0)
Only logged in customers who have purchased this product may leave a review.





























Reviews
There are no reviews yet.