Shipping Countries: United States (US)
BIOER SARS-CoV-2 / Respiratory Syncytial Virus /Influenza A Virus /Influenza B Virus Nucleic Acid Multiple Detection Kit (Fluorescence PCR) — Estimated US$633.6 / 48T
$633.60
Available in stock
Respiratory infection is one of the most common diseases, with adolescents and adults being infected about 2-4 times a year, and children being infected about 6-8 times a year.
Estimated equipment price only. Shipping, import duties, installation, and logistics are additional and vary by destination and shipping method. We will contact you to confirm the total cost before processing your order.
Scientific China
StorePeople Also Viewed
-
BIOER Bordetella Pertussis Nucleic Acid Detection Kit (Fluorescent PCR) — Estimated US$8.8 / 24-test reference quantity (assumed; confirm pack)
$8.80
-
BIOER Human Parainfluenza Virus Type 1, Type 2, Type 3 Nucleic Acid Detection Kit (Fluorescent PCR) — Estimated US$8.8 / 24-test reference quantity (assumed; confirm pack)
$8.80
-
BIOER Porcine-derived Nucleic Acid DetectionKit (Fluorescence PCR) — Estimated US$8.8 / 24-test reference quantity (assumed; confirm pack)
$8.80
-
BIOER BioEasy LAMP Kit (Visual Dye) — Estimated US$1.32 / 24-test reference quantity (assumed; confirm pack)
$1.32
-
BIOER BioRT One-step RT-qPCR Kit (UDG plus) — Estimated US$220 / 100T
$220.00
-
BIOER Bovine-derived Nucleic Acid Detection Kit (Fluorescence PCR) — Estimated US$8.8 / 24-test reference quantity (assumed; confirm pack)
$8.80
| Brand | BIOER |
|---|---|
| Sensitivity | 500 copies/mL |
| Accuracy | Be able to detect SARS-CoV-2, Respiratory Syncytial Virus, Influenza A Virus, Influenza B Virus Nucleic Acid simultaneously |
| Precision | Inter-assay, intra-assay, inter-day and intra-day precision CV less than 5% |
| Detection Time | 35 min |
| Compatible Instruments | Bioer’s Fluorescence Quantitative Detection System, LineGene 9600 Plus (FQD-96A) and QuantGene 9600(FQD-96C) |
| BSJ37M1 | Product Name: SARS-CoV-2/Respiratory Syncytial Virus/Influenza A Virus/Influenza B Virus Nucleic Acid Multiple Detection Kit (Fluorescence PCR); Packing Size: 48T |
| BSJ37L1 | Product Name: SARS-CoV-2/Respiratory Syncytial Virus/Influenza A Virus/Influenza B Virus Nucleic Acid Multiple Detection Kit (Fluorescence PCR); Packing Size: 96T |
Product Enquiry
Description
Respiratory infection is one of the most common diseases, with adolescents and adults being infected about 2-4 times a year, and children being infected about 6-8 times a year. It is usually accompanied by acute inflammation of the nasal cavity, pharynx, or throat, with most infections being viral, except for a few bacterial infections. SARS-CoV-2 Virus, Respiratory Syncytial Virus, Influenza A Virus and Influenza B Virus have strong transmission power. Epidemiological and clinical symptoms are very similar. Double transmission increases the difficulty of epidemic prevention and control. Therefore, it is an important guarantee for people's health to carry out the detection of COVID-19, influenza virus and other pathogens, do a good job in differential diagnosis, and take targeted prevention and control measures in time.
Product details
This kit uses highly conserved regions of SARS-CoV-2 Virus, Respiratory Syncytial Virus, Influenza A Virus and Influenza B Virus, and designs specific primer probes. The primers and probes can specifically bind to the target sequence. Under the action of reverse transcriptase and hot start Taq DNA polymerase, this segment is specifically amplified, and the fluorescent probe is hydrolyzed during amplification to generate fluorescence. The detection system contains dUTP-UDG enzyme to fully degrade potential product contamination and avoid false positive results; In addition, internal standards are set up to monitor the entire process of sample collection, transportation, nucleic acid extraction, and PCR amplification for highly conserved regions on the human genome, avoiding false negative results and ensuring the effectiveness of the entire process.
Applications
The kit is used for the auxiliarydiagnosis and epidemiological surveillance of SARS-COV-2, RSV,Flu A and FluB infection, cannot be used as the basis for the diagnosis or exclusion of cases alone.
Storage and handling
1. The kit should be stored at -25°C ~ -15°C away from light and avoid repeated freeze-thaw.
2. The kit can be stored for 3 days at 2-8°C after opening.
3. The kit can be stored for up to 12 months if all components are kept in the manner above. Do not use after the stated expiry date.
4. The kit can be transported in foam box sealed with ice bags or dry ice under 8°C.
Specifications
| Sample type | Nasopharyngeal swab |
|---|---|
| Sensitivity | 500 copies/mL |
| Accuracy | Be able to detect SARS-CoV-2, Respiratory Syncytial Virus, Influenza A Virus, Influenza B Virus Nucleic Acid simultaneously |
| Precision | Inter-assay, intra-assay, inter-day and intra-day precision CV less than 5% |
| Detection Time | 35 min |
| Compatible Instruments | Bioer’s Fluorescence Quantitative Detection System, LineGene 9600 Plus (FQD-96A) and QuantGene 9600(FQD-96C) |
| Certificate | CE-IVD |
Ordering information
| Cat# | Product Name | Packing Size |
|---|---|---|
| BSJ37M1 | SARS-CoV-2/Respiratory Syncytial Virus/Influenza A Virus/Influenza B Virus Nucleic Acid Multiple Detection Kit (Fluorescence PCR) | 48T |
| BSJ37L1 | SARS-CoV-2/Respiratory Syncytial Virus/Influenza A Virus/Influenza B Virus Nucleic Acid Multiple Detection Kit (Fluorescence PCR) | 96T |
Reviews (0)
Only logged in customers who have purchased this product may leave a review.













Reviews
There are no reviews yet.