GeneMind SURFSeq Q Ultra-High-Throughput Sequencing System
Available in stock
Scientific China
StorePeople Also Viewed
-
Kelun Dexmedetomidine Injection
-
Kelun Propofol Medium and Long Chain Fat Emulsion Injection
-
Kelun Ambroxol Hydrochloride and Sodium Chloride Injection
-
Kelun Alany Glutamine Injection
-
Kelun Compound Amino Acids (15) and Dipeptides (2) Injection
-
Kelun Fat Emulsion Injection (C14~24)
-
Kelun Vitamin C and Glucose Injection
-
Kelun Vitamin C and Sodium Chloride Injection
-
Kelun Fructose Injection
-
Kelun Fructose and Sodium Chloride Injection
| Q30 | Q40 |
|---|---|
| Weight | < 500 kg |
| Power requirements | < 6000 W |
| Operating environment | Temperature: 19 ℃ – 25 ℃ |
| Instrument control computer | Altitude:≤2000 m |
| Parameter | Description |
Product Enquiry
Description
GeneMind SURFSeq Q Ultra-High-Throughput Sequencing System
Product overview
SURFSeq Q is an ultra-high throughput sequencer with a worldwide superb daily data output capacity. By integrating several innovative technologies, such as high-speed chemistry, new patterned array sequencing flow cell, AI base recognition algorithm, and other innovative technologies, SURFSeq Q can achieve the Q40 score >=90% with a powerful productivity of 9Tb per day in a single run. Its superior data delivery capabilities and high accuracy can efficiently support scientific discovery and sequencing services, such as extensive population cohort studies and single-cell and spatial omics research.
Key features
- Super Data Output: Ultra-high throughput: 14Tb/run Powerful productivity: 9Tb/day, 20000+ WGS(30X)/year
- Ultra-high Data Quality: Innovative sequencing chemistry+ AI based recognition algorithm Capable of producing>=90% of output bases with a Q40 score
- User-friendly Design: Automated individual lane loading for up to eight lanes per flow cell Allow customer to obtain data from different applications of the same sequencing run Support to resuming from the break-point continue sequencing Post-run wash performed automatically after every sequencing run
Applications
Genome sequencing, targeted sequencing, transcriptomics, metagenomics, molecular research, and other next-generation sequencing workflows.
Sequencing performance
| Flow cell | Lane | Throughput(Reads/FC) | Type | Read Length | Data output | Q value | TAT | |
|---|---|---|---|---|---|---|---|---|
| Q30 | Q40 | |||||||
| FCM | 4 | 11.7 B | 50cycles | SE50 | 0.6 Tb×2 | ≥90% | ≥90% | 10 hr |
| 100cycles | SE100 | 1.2 Tb×2 | ≥90% | ≥90% | 13 hr | |||
| PE50 | 1.2 Tb×2 | ≥90% | ≥90% | 13 hr | ||||
| 200cycles | PE100 | 2.3 Tb×2 | ≥90% | ≥90% | 19 hr | |||
| 300cycles | PE150 | 3.5 Tb×2 | ≥90% | ≥90% | 24 hr | |||
| FCH | 8 | 23.3 B | 50 cycles | SE50 | 1.2 Tb×2 | ≥90% | ≥90% | 17 hr |
| 100 cycles | SE100 | 2.3 Tb×2 | ≥90% | ≥90% | 22 hr | |||
| 200 cycles | PE100 | 4.7 Tb×2 | ≥90% | ≥90% | 29 hr | |||
| 300 cycles | PE150 | 7 Tb×2 | ≥90% | ≥90% | 36 hr |
Applications and sample capacity
| Application | Data/sample | FCM*1 | FCH*1/FCM*2 | FCM*1+FCH*1 | FCH*2 |
|---|---|---|---|---|---|
| 11.7 B | 23.3 B | 35B | 46.6B | ||
| WGS | 120Gb/sample | 24 | 48 | 72 | 96 |
| scRNA-seq | 60Gb/sample | 48 | 96 | 144 | 192 |
| ctDNA | 30Gb/sample | 96 | 192 | 288 | 384 |
| RNAseq | 10Gb/sample | 288 | 576 | 864 | 1152 |
| WES | 10Gb/sample | 288 | 576 | 864 | 1152 |
| Single cell | 60Gb/sample | 48 | 96 | 144 | 192 |
Instrument specifications
| Dimensions W × D × H | 975 mm × 921 mm×1570 mm |
|---|---|
| Weight | < 500 kg |
| Power requirements | < 6000 W |
| 200-240 V~,50/60 Hz | |
| Operating environment | Temperature: 19 ℃ – 25 ℃ |
| non-condensing:20‒80% relative humidity | |
| Instrument control computer | Altitude:≤2000 m |
| CPU:Intel Xeon Gold 6326 ×2 | |
| Memory: 2 TB | |
| Solid-state drive: 3.7 TB | |
| Hard disk drive: 76.3 TB | |
| Operating system: Windows 10 ×64 |
Additional technical information
| Description of Read Header | |
|---|---|
| Parameter | Description |
| <SN> | Serial number of the instrument. |
| <Barcodescore> | Numbers 0 to 9 are used to evaluate the sequencing quality value of the index sequence. The higher the value, the better the quality. |
| <Flowcell ID> | The ID of the sequence chip. |
| <Lane> | Number of the lane, it can be L00、L01、L02、L03、L04, etc. L00 indicates that all lanes are merged. |
| <FOV> | Coordinate of the FOV. |
| <X> | X-coordinate of the cluster. |
| <Y> | Y-coordinate of the cluster. |
| <read1/2> | Read 1 or Read 2. |
| <N> | Default character. |
| <0> | Default character. |
| <Index> | The sequence of the index, if it is a combination of index1 and index2, it should be concatenated with symbol”+”. |
| Note:@<SN>:<Barcodescore>:<Flowcell ID>:<Lane>:<FOV>:<X>:<Y> <read1/2>:<N>:<0>:<Index> The header identifier is represented by the symbol “@”, while the parameter items are differentiated using the symbol “:”. |
Ordering and configuration
Contact Scientific China for availability, supported configurations, compatible consumables, minimum order quantity, installation requirements, lead time, and a formal quotation for the GeneMind SURFSeq Q Ultra-High-Throughput Sequencing System.
Reviews (0)
Only logged in customers who have purchased this product may leave a review.














































































Reviews
There are no reviews yet.