Shipping Countries: United States (US)

Novel Optics Glass Lens — Estimated US$50 / unit
Available in stock
Spherical and aspheric glass optics for imaging, illumination and optical-system integration. Application areas: Medical Optics, Automotive Optics, Barcode & Machine Vision, Professional Imaging, Specialized Optics; Manufacturer lists: Polishing, Coating, Cementing, Edge Blackening, Molding, Edge Grinding, Edge‑Grinding.
Estimated equipment price only. Shipping, import duties, installation, and logistics are additional and vary by destination and shipping method. We will contact you to confirm the total cost before processing your order.
Scientific China
StorePeople Also Viewed
-
Novel Optics Prism — Estimated US$60 / unit
-
Novel Optics Rod Lens — Estimated US$100 / unit
$100.00
-
Novel Optics Glass Lens — Estimated US$50 / unit
$50.00
-
Novel Optics Modular Microscope Components — Estimated US$350
$350.00
-
Novel Optics Tube-lens Assembly — Estimated US$450
$450.00
-
Novel Optics Stand Frame — Estimated US$700
$700.00
Description
Spherical and aspheric glass optics for imaging, illumination and optical-system integration.
Technical details and specifications
- Application areas: Medical Optics, Automotive Optics, Barcode & Machine Vision, Professional Imaging, Specialized Optics
- Manufacturer lists: Polishing, Coating, Cementing, Edge Blackening, Molding, Edge Grinding, Edge‑Grinding
- Diameter: φ0.8–φ20 mm
- Radius of Curvature: R > 0.5 mm
- Center Thickness Tolerance: ±0.01 mm
- Surface Imperfections: 2 × 0.0063
- Surface Form: 1 (0.2)
Manufacturer capability tables
These figures describe manufacturing capabilities across the product family. The approved drawing determines the actual combination of material, dimensions, coating and tolerances.
| Key Parameters | Capabilities | Inspection Equipment |
| Diameter | φ0.8–φ20 mm | Digital Micrometer |
| Radius of Curvature | R > 0.5 mm | Interferometer and Laser Distance Meter |
| Center Thickness Tolerance | ±0.01 mm | Digital Micrometer |
| Surface Imperfections | 2 × 0.0063 | Microscope |
| Surface Form | 1 (0.2) | Optical Test Plate / Interferometer |
| Filter Type | Standard Performance | High-Precision Performance |
| AR (+ Anti-Fog) Coating | UV/VIS/NIRAverage reflectance <0.4% | UV/VIS/NIRAverage reflectance <0.2% |
| Notch Filter | VIS/NIRAverage transmission >90%, OD 4 | VIS/NIRAverage transmission >95%, OD 7 |
| Key Parameters | Capabilities | Inspection Equipment |
| Diameter | 1–20 mm | Digital Micrometer |
| Reflection Centration Error | 0.5′ (3 μm) | Optical Centration Tester |
| Local Optical Axis Error | 0.2λ | Interferometer |
| Reliability | Withstands temperatures up to 134°C | High/Low Temperature Test Chamber |
| Key Parameters | Capabilities | Inspection Equipment |
| Diameter (Before Blackening) | 2–20 mm | Digital Micrometer |
| Diameter Tolerance (After Blackening) | ±0.005 mm | Digital Micrometer |
| Ink Overflow | 0.05 mm | Vision Measuring System |
| Ink Underrun | 0.05 mm | Vision Measuring System |
| Key Parameters | Capabilities | Inspection Equipment |
| Diameter | 2.5–10 mm | Digital Micrometer |
| Center Thickness Tolerance | ±0.005 mm | Digital Micrometer |
| Surface Form Accuracy | PV ≤ 0.4 μm, RMS ≤ 0.2 μm | UA3P Profilometer |
| Centering Error | 3 μm | UA3P Profilometer |
| Surface Imperfections | 2 × 0.1 | Visual Inspection or Microscope |
| Key Parameters | Capabilities | Testing Equipment |
| Materials | IR materials, optical glass, Si, fused silica, etc. | Refractometer |
| Diameter | Φ2-Φ100 mm | Digital Micrometer |
| Radius of Curvature | R > 0.5 mm | Interferometer + Laser Distance Meter |
| Center Thickness Tolerance | ±0.01 mm | Optical Thickness Gauge |
| Surface Defects | 2×0.10 | Visual inspection or microscope |
| Surface Figure | 1 (0.2) | Interferometer |
| Key Parameters | Capabilities | Testing Equipment |
| Diameter | 0.8-100 mm | Digital Micrometer |
| Reflected Decenter | 1′ (0.005 mm) | Optical Centering Instrument |
| Transmitted Decenter | 0.5′ (0.005 mm) | Optical Centering Instrument |
| Diameter Tolerance | ±0.005 mm | Digital Micrometer |
| Sag Tolerance | ±0.005 mm | Digital Micrometer |
| Key Parameters | Capabilities | Testing Equipment |
| Diameter | 1-100 mm | Digital Micrometer |
| Reflected Decenter | 0.5′ (3 μm) | Optical Centering Instrument |
| Surface Figure | 1 (0.2) | Interferometer |
| Key Parameters | Capabilities | Inspection Equipment |
| Diameter | 1.2-50 mm | Digital Micrometer |
| Center Thickness Tolerance | ±0.005 mm | Digital Micrometer |
| Surface Figure Accuracy | PV ≤ 0.5 µm, RMS ≤ 0.2 µm | UA3P Profilometer |
| Centration Error | 3 µm | UA3P Profilometer |
| Surface Imperfection | 2×0.1 | Visual Inspection or Microscope |
| Key Parameters | Capabilities | Inspection Equipment |
| Materials | Infrared materials, optical glass, Si, quartz, etc. | Refractometer |
| Diameter | Φ2–Φ80 mm | Digital Micrometer |
| Radius of Curvature | R > 0.5 mm | Interferometer and Laser Distance Meter |
| Center Thickness Tolerance | ±0.01 mm | Optical Thickness Gauge |
| Surface Imperfections | 2 × 0.10 | Visual Inspection or Microscope |
| Surface Form | 1 (0.2) | Interferometer |
| Key Parameters | Capabilities | Inspection Equipment |
| Diameter | 2–80 mm | Digital Micrometer |
| Reflection Centration Error | 1′ (0.005 mm) | Optical Centration Tester |
| Transmission Centration Error | 0.5′ (0.005 mm) | Optical Centration Tester |
| Diameter Tolerance | ±0.005 mm | Digital Micrometer |
| Sag Tolerance | ±0.005 mm | Digital Micrometer |
| Key Parameters | Capabilities | Inspection Equipment |
| Diameter | 2–80 mm | Digital Micrometer |
| Reflection Centration Error | 0.5′ (3 μm) | Optical Centration Tester |
| Surface Form | 1 (0.2) | Interferometer |
| Key Parameters | Capabilities | Inspection Equipment |
| Diameter | 2-50 mm | Digital Micrometer |
| Center Thickness Tolerance | ±0.005 mm | Digital Micrometer |
| Surface Figure Accuracy | PV ≤ 0.5 µm, RMS ≤ 0.2 µm | UA3P Profilometer |
| Centration Error | 3 µm | UA3P Profilometer |
| Surface Imperfection | 2×0.1 | Visual inspection or Microscope |
| Key Parameters | Standard Performance | Best Performance | Inspection Equipment |
| Diameter | 2–35 mm | 1.2–50 mm | Digital Micrometer |
| Center Thickness Tolerance | ±0.01 mm | ±0.005 mm | Digital Micrometer |
| Surface Form Accuracy | PV ≤ 0.8 μmRMS ≤ 0.4 μm | PV ≤ 0.4 μmRMS ≤ 0.2 μm | UA3P Profilometer |
| Centering Error | 5 μm | 3 μm | UA3P Profilometer |
| Surface Imperfections | 3 × 0.25 | 2 × 0.1 | Visual Inspection or Microscope |
| Key Parameters | Capabilities | Inspection Equipment |
| Materials | Infrared materials, optical glass, Si, quartz, etc. | Refractometer |
| Diameter | Φ2–Φ200 mm | Digital Micrometer |
| Radius of Curvature | R > 0.5 mm | Interferometer and Laser Distance Meter |
| Center Thickness Tolerance | ±0.01 mm | Optical Thickness Gauge |
| Surface Imperfections | 2 × 0.10 | Visual Inspection or Microscope |
| Surface Form | 1 (0.2) | Interferometer |
| Key Parameters | Capabilities | Inspection Equipment |
| Diameter | 0.8-200 mm | Digital Micrometer |
| Reflected Centration Error | 1′ (0.005 mm) | Optical Centering Instrument |
| Transmitted Centration Error | 0.5′ (3 mm) | Optical Centering Instrument |
| Diameter Tolerance | ±0.005 mm | Digital Micrometer |
| Sag Tolerance | ±0.005 mm | Digital Micrometer |
| Key Parameters | Capabilities | Inspection Equipment |
| Diameter | 1–150 mm | Digital Micrometer |
| Reflection Centration Error | 0.5′ (3 μm) | Optical Centration Tester |
| Surface Form | 1 (0.2) | Interferometer |
| Key Parameters | Capabilities | Inspection Equipment |
| Diameter | 1.2–50 mm | Digital Micrometer |
| Center Thickness Tolerance | ±0.005 mm | Digital Micrometer |
| Surface Form Accuracy | PV ≤ 0.5 µm, RMS ≤ 0.2 µm | UA3P Profilometer |
| Centering Error | 3 µm | UA3P Profilometer |
| Surface Imperfections | 2 × 0.1 | Visual Inspection or Microscope |
Configuration and ordering
Reference configuration: one representative glass lens; final drawing, material, coating and quantity to be confirmed.
The title shows an indicative budget estimate based on comparable optical components and assembly complexity. It is not a confirmed Novel Optics quotation.
Custom tooling, non-recurring engineering, qualification testing and host-system integration are excluded unless expressly itemized.
Photographs may show different configurations or optional accessories within this product family. Only items expressly listed in the confirmed order are included.
Manufacturer product information
Buying questions answered
What is the glass lens used for?
Spherical and aspheric glass optics for imaging, illumination and optical-system integration.
What information is needed to select or manufacture this part?
Provide the optical drawing or host model, wavelength range, clear aperture, material, coatings, mechanical interface, tolerances and order quantity. Published capability examples include Manufacturer lists: Polishing, Coating, Cementing, Edge Blackening, Molding, Edge Grinding, Edge-Grinding; Diameter: φ0.8–φ20 mm. The final drawing and inspection criteria require supplier approval.
Do all listed manufacturing capabilities apply to every supplied part?
No. These are manufacturer capability examples for this product family. Material, diameter, surface finish, coating and tolerance combinations must be confirmed together for the approved drawing. They are not a guaranteed specification for every variant.
Is this a complete instrument or a component?
The reference estimate covers one representative glass lens; final drawing, material, coating and quantity to be confirmed. It does not include a complete host instrument, tooling, engineering development, certification or system integration unless the written order expressly includes them.
Are prototype quantities and custom coatings available?
Novel Optics describes customization for this family. Minimum order quantity, prototype charges, coating batch charges, tooling ownership and repeat-order pricing are not publicly fixed and must be confirmed for the drawing and quantity.
What does the estimated price exclude?
Shipping, import duties, installation and logistics are additional. Optional optics, accessories, software licenses, engineering and integration are separate unless expressly included. The final configuration and total cost will be confirmed before processing the order.
What are the warranty and after-sales arrangements?
A fixed warranty term or local on-site service package has not been verified for this supply route. The written offer must state coverage, parts and labor, remote support, repair location and responsibility for return freight.
What is the lead time and is stock available?
Current stock, production time and delivery date require confirmation for the chosen configuration, quantity and destination. No fixed dispatch or delivery promise is made in this listing.
Reviews (0)
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.