Hanon E500 Organic Elemental Analyzer — Estimated US$95,000
Available in stock
The E500 measures the elemental composition of organic solid and liquid samples using configured combustion and oxygen-analysis modes. C, H, N, S and O analysis modes; 120-position crucible autosampler listed.
Estimated equipment price only. Shipping, import duties, installation, and logistics are additional and vary by destination and shipping method. We will contact you to confirm the total cost before processing your order.
Scientific China
StorePeople Also Viewed
-
Novel Optics NOS1000 Structured-Light Optical-Sectioning Microscope — Estimated US$100,000
-
Novel Optics NCF1000 Laser Confocal Microscope — Estimated US$225,000
-
Novel Optics NCF2000 Laser Confocal Microscope — Estimated US$300,000
-
Novel Optics NSR1000 Super-Resolution Microscope — Estimated US$425,000
-
Hanon F2000 Automatic Fiber Analyzer — Estimated US$22,000
-
Hanon DF06 Dietary Fiber Analyzer — Estimated US$16,000
| Manufacturer / Group | Hanon (Hanon Group) |
|---|---|
| Model / Product Family | E500 |
Product Enquiry
Description
The E500 measures the elemental composition of organic solid and liquid samples using configured combustion and oxygen-analysis modes.
Technical details and specifications
- C, H, N, S and O analysis modes
- 120-position crucible autosampler listed
- Combustion temperature capability up to 1400 °C
- TCD used for CHNS and NDIR for the oxygen mode in published specifications
- CHNS and oxygen configurations must be itemized rather than assumed simultaneous
Published reference specifications
These figures describe a listed configuration. Confirm the current supplied revision, included accessories and destination power before ordering.
| Autosampler | 120-position sample tray; sample introduction in crucibles; in-situ crucible replacement at high temperature |
|---|---|
| Gas separation method | Adsorption–desorption separation |
| High-temperature combustion and reduction | Combustion temperature up to 1400 °C, ensuring complete combustion of the sample |
| Analysis time | Approx. 3–4 min per element |
| Sample size | Max. 1.5 g or a sample volume of 1 ml |
| Detection range | Maximum dynamic range of element content: C 0–30 mg absolute or 0–100%; H 0–4 mg absolute or 0–100%; N 0–10 mg absolute or 0–100%; S 0–5 mg absolute or 0–100%; O 0–3 mg absolute or 0–100% |
| Repeatability error | Standard deviation <0.1% (10 mg sulfadiazine standard) |
| Detection limit | C, H, N, S: <30 ppm (TCD detector); O: <20 ppm (IR detector) |
| Detectors | C/H/N/S mode: thermal conductivity detector (TCD); O mode: non-dispersive infrared detector (NDIR) |
| Working gases | Carrier gas: helium (He), purity 99.999%; combustion gas: oxygen (O₂), purity 99.999% |
| Dimensions (L × W × H) | 735 × 560 × 1160 mm (including autosampler) |
| Net weight | 100 kg (including autosampler) |
| Power supply | 220 V AC ±10%, 50 Hz |
| Computer | PC running Windows 7 or later, with a USB or RS232 interface |
| Operating ambient temperature | 15–30 °C |
| Relative humidity | ≤85% |
Configuration and ordering
Reference configuration: one E500 organic elemental analyzer with CHNS configuration and standard sampler; oxygen-mode scope to be quoted separately.
The title shows an indicative budget based on comparable configurations and public market references. It is not a confirmed manufacturer quotation.
Manufacturer product information | Hanon group catalog
Buying questions answered
What elements or analytes does this configuration measure?
The E500 family offers CHNS and oxygen-related configurations. The reference estimate is a CHNS setup; oxygen-mode hardware and operation must be confirmed separately.
What consumables and gas infrastructure are required?
Confirm carrier and combustion gases, purity / pressure specifications, regulators, combustion and reduction tubes, capsules or crucibles, standards, balance, exhaust and ash-handling requirements. These create recurring costs.
Does the family price cover every model or sampler?
The reference is one E500 organic elemental analyzer with CHNS configuration and standard sampler; oxygen-mode scope to be quoted separately. The sampler count, detector / mode package and workstation are configuration-specific; a family photograph does not mean every illustrated module is included.
What does the equipment estimate exclude?
Shipping, import duties, installation and logistics are additional. Optional modules, recurring reagents / consumables, software licenses, certification and integration are separate unless expressly included. The final configuration and total cost will be confirmed before order processing.
What warranty and after-sales support are included?
A fixed warranty term or local on-site service package has not been verified for this supply route. The written quotation must state parts / labor coverage, remote support, repair location and responsibility for return freight.
What are the lead time, stock and destination-power arrangements?
Stock, production and delivery dates require confirmation for the selected model, quantity and destination. Confirm the actual input voltage, frequency, plug and installation requirements before order processing; no fixed dispatch date or universal power specification is promised.
Reviews (0)
Only logged in customers who have purchased this product may leave a review.










Reviews
There are no reviews yet.