Shipping Countries: United States (US)
Drawell ICP900T Full Spectrum Direct Reading Inductively Coupled Plasma Emission Spectrometer
Available in stock
The Drawell ICP900T Full Spectrum Direct Reading Inductively Coupled Plasma Emission Spectrometer is a professional analytical laboratory instrument. Review features and technical specifications, then request configuration, MOQ, lead time, warranty, and a formal quotation.
Scientific China
StorePeople Also Viewed
| Product Category | Spectrophotometer > ICP Emission Spectrometer(ICP-OES/AES) |
|---|
Product Enquiry
Description
Drawell ICP900T Full Spectrum Direct Reading Inductively Coupled Plasma Emission Spectrometer
Product overview
ICP900T the full spectrum direct reading inductively coupled plasma emission spectrometer is used to determine the content of major, trace, and trace elements in different samples. It can be used for qualitative, semi quantitative, and precise quantitative analysis of elements in samples, with a detection limit of up to one part per billion. Widely used in environmental, food, geological, metallurgical, chemical, petroleum, semiconductor, clinical, and agricultural analysis.
The Drawell ICP900T Full Spectrum Direct Reading Inductively Coupled Plasma Emission Spectrometer supports research, pharmaceutical, environmental, food, industrial, and quality-control laboratories. Scientific China provides model selection, configuration review, export coordination, and formal quotations.
Key features
- 1. 70+ Elements Testing
- Supports simultaneous multi-element analysis.
- 2. One Injection, Full Results
- All selected elements measured in a single run.
- 3. 1 Sample/Min
- Fast analysis for high-throughput testing.
- 4. ppb-Level Detection
- Achievable for most elements.
- 5. 5–6 Orders Linear Range
- Measures high and low concentrations with one calibration curve.
- 6. Minimal Chemical Interference
- Improves result accuracy and reliability.
- Its core advantage is “full-spectrum direct reading.” With a single injection and excitation, it can simultaneously detect all measurable elements in a sample (up to 70), eliminating the need for element-by-element scanning as required by sequential scanning instruments, thus greatly improving analytical efficiency.
- The detection limit is very low, with most elements reaching the ppb level (parts per billion), which can meet the analytical needs of trace and ultra-trace elements. It is suitable for the detection of high-purity materials or trace pollutants in the environment.
Applications
- Environmental protection industry
- Accurately and quickly analyze the elemental composition of environmental samples(water quality, soil, atmosphere), providing protection for human daily life.
- Rare earth industry
- The value and use of rare earth elements are increasingly favored, and the application range of high-purity rare earth elements is also becoming wider. The analysis of impurity elements is particularly important, and the accuracy and efficiency required for rare earth testing can be fully met.
Technical specifications
| Input power supply | AC 220V, current 20A |
|---|---|
| Input power | 700-1500W |
| Power Efficiency | Greater than 70% |
| Output power stability | <0.01% |
| Power frequency | 27.12MHz |
| Frequency Stability | <0.01% |
| Observation method | Vertical observation |
| Stability | Relative standard deviation RSD<l% @ 2 hours |
| Element detection limit (ug/) | Most elements range from lppb to 10ppb |
| Repeatability | (i.e. short-term stability) relative standard deviation RSD<0.5%% |
| Test speed | The reading time of a single spectral line CID is only 2 seconds, and all elements can be measured within 20 seconds |
| Output working coil | silver plated high-firequency coil with an inner diameter of 25mm and 3 turns |
| Total argon consumption | The total argon consumption is less than l4L/min |
| Atomization chamber | Double tube atomization chamber, optional with swirl atomization chamber |
| Peristaltic pump | five channels and sixteen rollers, with adjustable speed according to the required flow rate |
| Three concentric quartz torch tube | outer diameter 20mm; Multiple models available in different industries |
| Efficient imported atomizer | concentric circular atomizer with an outer diameter of 6mm, Multiple models available, high salt, Hf resistant, etc |
| Detector type | American original Thermo Charge Injection Detector (CD) |
| Target size | 27.6×27.6mm,1024 |
| Quantum efficiency | No coating, up to 35% in the 200nm ultraviolet region |
| Detector cooling | high-efficiency three-level semiconductor cooling, cooling temperature -45℃ |
| Reading methods | Non destructive reading (NDRO), full amplitude reading (F), and arbitrary read integration (RAI) |
| Grating | medium stepped grating, 52.67lp/mm, 64° flare angle |
| Light chamber | distributed precision constant temperature, 35 + 0.1 ° |
| Prism | ultrapure Corning ultraviolet fused silica, with filtration greater than 99% at 170nm |
| Stray light | Equivalent background concentration of 10000ppmCa solution at As189.042nm<2ppm |
| Serial Number | Accessory Name | Quantity | Unit | Specification A nd M odel | Notes |
|---|---|---|---|---|---|
| One | Standard C onfiguration | ||||
| 1 | Host | ||||
| 1.1 | Inductively coupled plasmaemission spectrometer | 1 | Set | ||
| 2 | Software | ||||
| 2.1 | ICP spectrometer analysissoftware | 1 | Set | Free upgrade | |
| 3 | A ccessory | ||||
| 3.1 | Network cable | 1 | Piece | 3m | |
| 3.2 | Plastic bucket | 1 | Piece | Volume 5L | |
| 3.3 | Argon pressure reducing valve | 2 | Piece | AR-8 | |
| 3.4 | PU hose | 30 | Meter | 10×6.5×1.75mm | |
| 3.5 | PU hose | 5 | Meter | 6×4×1mm | |
| 3.6 | PVC transparent hose | 1 | Meter | 8mm×6mm Transparent hose | |
| 3.7 | Power cord | 1 | Piece | 10A,250V | |
| 3.8 | USB extension cable | 1 | Piece | Length 3m | |
| 3.9 | Grounding copper wire | 15 | Meter | Sectional area 4mm² | |
| 3.10 | Ground rod | 1 | Piece | 18*800 | |
| 3.11 | Torch tube | 2 | Piece | 1.5 quartz torch tube | |
| 3.12 | Double tube fog chamber | 1 | Piece | Scott fog chamber | |
| 3.13 | Cylindrical fog chambercover | 1 | Piece | Polytetrafluoroethylene | |
| 3.14 | Atomizer | 1 | Piece | Quartz atomizer | |
| 3.15 | Wavelength calibration solution | 1 | Bottle | 1000ml | |
| 3.16 | High-frequency coil component | 1 | Piece | Three turns ,silver plating | |
| 3.17 | Capillary sample tube | 1 | Meter | D=2.38mm,d=0.8mm | |
| 3.18 | Peristaltic pump head hose | 3 | Piece | Ф1.65,Length 45cm,Two clamps | |
| 3.19 | Tubular fuse | 2 | Piece | 10A,250V,6×30mm | |
| 3.20 | Tubular fuse | 2 | Piece | 6.3A,250V,5×20mm | |
| 3.21 | Silicone tube | 4 | Meter | Inside diameter 2mm,Outside diameter 4mm,Hardness 55 | |
| 3.22 | Hose adapter | 4 | Piece | ZCJH-2*6 direct connection,Inside diameter 6-2 | |
| 3.23 | Hose adapter | 4 | Piece | ZC-1/16*3/32,Inside diameter 1.6-2.4 | |
| 3.24 | Spherical interface clamp | 1 | Piece | L00091181,Ø=10 | |
| 3.25 | Quick coupling | 3 | Piece | Φ6 | |
| 3.26 | Teflon tape | 1 | Roll | Thickness:0.1~0.2mm | |
| 3.27 | O-ring seal | 4 | Piece | 32.5×3.55 | |
| 3.28 | O-ring seal | 8 | Piece | 5.6×1.8 | |
| 3.29 | Torch pipe tooling | 1 | Piece | Cylinder | |
| 3.30 | Nylon cloth ventilation duct | 10 | Meter | Grey,Inside diameter 125mm | |
| 3.31 | Stainless steel pipe clamp | 2 | Piece | 118-140mm | |
| 3.32 | Ribbon | 50 | Piece | 4×200 | |
| 3.33 | Screw | 5 | Piece | M5,Cross dischead | |
| 3.34 | Screw | 5 | Piece | M4,Cross dischead | |
| 3.35 | T-shaped tee | 2 | Piece | 10-10-10 | |
| 3.36 | Filter tank filter element | 4 | Piece | Outside diameter:60mm,Inside diameter:28mm,Length:125mm | |
| 4 | Standard C onfiguration | ||||
| 4.1 | Computer | 1 | Set | Brand | |
| 4.2 | Monitor | 1 | Set | Brand | |
| 4.3 | Printer | 1 | Set | Brand | |
| 4.4 | Cooling water tank | 1 | Set | ||
| 4.5 | Regulated power supply | 1 | Set | ||
| 5 | Delivery Attached Documenta tion | ||||
| 5.1 | U disk | 1 | Piece | ||
| 5.2 | Product quality certificate | 1 | Piece | English | |
| 5.3 | Warranty card | 1 | Piece | English |
| No. | Name | Specification | Replacement cycle |
|---|---|---|---|
| 1 | Torch | Quartz torch | Clean and maintain once every 3 months.Service life 2 years |
| 2 | Nebulizer | Import GE nebulizer | Non-human damage over 3 years |
| 3 | Spray chamber | Double-tube spray chamber | Non-human damage over 3 years |
| 4 | Peristaltic Pump Head Hose | Injection and Drain Tubing | 3 Months |
| 5 | High- frequency coil | Silver-plated, three-turn coil | One year |
| 6 | Filter element | PP cotton material | Half a year |
Ordering and configuration
Final specifications, included accessories, consumables, software, certifications, power requirements, installation, warranty, and regulatory availability depend on the selected model and destination. Contact Scientific China to confirm the suitable configuration, minimum order quantity, price, lead time, documentation, and international delivery terms before purchase.
Reviews (0)
Only logged in customers who have purchased this product may leave a review.























Reviews