Shipping Countries: United States (US)
Drawell ICP-OES MICS Full Spectrum Direct Reading Inductively Coupled Plasma Emission Spectrometer
Available in stock
The Drawell ICP-OES MICS Full Spectrum Direct Reading Inductively Coupled Plasma Emission Spectrometer is a professional analytical laboratory instrument. Review features and technical specifications, then request configuration, MOQ, lead time, warranty, and a formal quotation.
Scientific China
StorePeople Also Viewed
| Product Category | Spectrophotometer > ICP Emission Spectrometer(ICP-OES/AES) |
|---|
Product Enquiry
Description
Drawell ICP-OES MICS Full Spectrum Direct Reading Inductively Coupled Plasma Emission Spectrometer
Product overview
ICPOES MICS Full-spectrum direct-reading inductively coupled plasma atomic emission spectrometers are used to determine the content of major, trace, and micro elements in various substances. They can be used for qualitative, semi-quantitative, and precise quantitative analysis of elements in samples, with detection limits as high as parts per billion. They have wide applications in environmental protection, food safety, geology and mineral resources, metallurgy, non-ferrous metals, rare earths, chemicals, clinical medicine, petroleum products, semiconductors, and agricultural research.
The Drawell ICP-OES MICS Full Spectrum Direct Reading Inductively Coupled Plasma Emission Spectrometer supports research, pharmaceutical, environmental, food, industrial, and quality-control laboratories. Scientific China provides model selection, configuration review, export coordination, and formal quotations.
Key features
- High degree of instrument automation
- The automation level of the instrument is extremely high, and all operations except for the power switch are completed by software. Intelligent software that can provide real-time feedback and information prompts for various operations
- One second positioning of torch tube position
- The torch tube auxiliary installation tool using patented technology can accurately achieve a concentric circle structure between the torch tube and the coil position, while ensuring that there is no deviation in the position and ensuring the stability of the test signal.
- Real time monitoring system for plasma flames
- Equipped with a real-time full color camera system, the operator can see the running graphics of the plasma in real-time full color in the control software of the instrument, and observe whether the torch tube and the center tube of the torch tube are dirty and need to be cleaned.
- Testing speed beyond imagination
- A testing speed of 20s can be set to an appropriate integration time for measurement. The integrated intensity values of all analytical spectral lines can be read out in one exposure. Accurate measurement of nearly 70 elements in a single sample within one minute.
- Convenient wavelength calibration function
- Intelligent automatic wavelength calibration algorithm, the software automatically performs wavelength calibration after startup, greatly saving time and cost for wavelength calibration.
- Fully automatic ignition and matching technology
- The software can fully automatically ignite with one click, and all parameter settings are automatically changed. With advanced automatic matching technology, the ignition success rate is high and the operation is simple.
- Separate injection system
- The split design of the fog chamber and torch tube reduces the impact of temperature changes in the combustion chamber on atomization efficiency, making it more intuitive to observe the real-time injection status. Equipped with patented technology, the extended mist chamber effectively separates gas and liquid, reducing interference from water vapor.
Applications
- Quantitative or qualitative laboratory analysis
- Research, method development, and routine quality control
- Application-specific testing with suitable accessories and methods
Technical specifications
| High-frequency generator | |
|---|---|
| Circuit type | All solid-state RF power supply Input power supply: 220V, 30A |
| Operating Frequency | 27.12MHz |
| Frequency Stability | <0.01% |
| Output power | 800W~1500W |
| Output power stability | ≤0.01% |
| Electromagnetic field leakage radiation intensity | At a distance of 30cm from the chassis, electric field: E< 10V/m: Magnetic field: H < 0.2A/m |
| Gas control flow rate size | Plasma gas flow meter:(l~20)L/min Auxiliary gas flow meter.(0.05~1.0)L/minCarrier gas flow meter :(0.05~1.0)L/min |
| Cooling water | The water temperature range is 20 °C~25 °C, the flow rate is greater than 7 L/min, the water pressure is greater than 0.1MPa, and the cooling water resistance is greater than 1MΩ |
| Polychromator | |
| light path | Middle step grating+prism cross dispersion type |
| Focal length | 440mm |
| Grating specifications | Echelle grating |
| Wavelength range | 175nm~870nm |
| Nitrogen purge | High speed blowing 6L/min, normal blowing 2L/min |
| CCD | |
| Detection wavelength range | l65nm ~ 900nm |
| Quantum efficiency | >30%@200nm |
| Refrigeration temperature | -45℃ |
| Nitrogen purging flow rate | 3L/min |
| Technical indicators of the entire machine | |
| Wavelength range | 175nm~900nm |
| Repeatability | Relative standard deviation RSD < l.5 % |
| Stability | Relative standard deviation RSD < l.0 % |
| Series Number | Accessory Name | Quantity | Unit | Specification and model | Notes |
|---|---|---|---|---|---|
| 一 | Standard configuration | ||||
| 1 | Host | ||||
| 1. 1 | Full spectrum direct reading inductively coupled plasma emission spectrometer | 1 | Set | ||
| 2 | Software | ||||
| 2. 1 | ICP full spectrum scanning spectro meter analysis software | 1 | Set | Lifetime free upgrade | |
| 3 | Accessory | ||||
| 3. 1 | Network cable | 1 | Piece | Category 5 twisted pair Cables 3m | |
| 3.2 | Plastic bucket | 1 | Piece | Volume 5L | |
| 3.3 | Argon pressure reducing valve | 2 | Piece | YQAR-8 | |
| 3.4 | PU Hose | 30 | Meter | 10×6.5×1.75mm | |
| 3.5 | PU Hose | 10 | Meter | 6×4×1mm | |
| 3.6 | PVC Transparent hose | 1 | Meter | 8mm×6mm Transparent hose | |
| 3.7 | Power cord | 1 | Piece | 10A,250V | |
| 3.8 | USB extension cable | 2 | Piece | Length 3m | |
| 3.9 | Grounding copper wire | 15 | Meter | 4mm² | |
| 3.10 | Ground rod | 1 | Piece | Length 500mm | |
| 3. 11 | Filter tank filter element | 2 | Piece | Outside diameter:60mm,Inside diameter:28mm,Length :125mm | |
| 3. 12 | Torch tube | 2 | Piece | Quartz torch tube | |
| 3.13 | Double tube fog chamber | 1 | Piece | Scott fog chamber | |
| 3. 14 | Atomizer | 1 | Piece | Quartz atomizer | |
| 3.15 | High-frequency coil component | 1 | Piece | ||
| 3.16 | Capillary sample tube | 1 | Meter | D=2.38mm,d=0.8mm | |
| 3.17 | Peristaltic pump head hose | 3 | Piece | Ф1.65,Length 45cm,Two clamps | |
| 3.18 | Tubular fuse | 2 | Piece | 10A,250V,6×30mm | |
| 3.19 | Tubular fuse | 2 | Piece | 6.3A,250V,5×20mm | |
| 3.20 | Cylindrical fog chamber cover | 1 | Piece | Polytetrafluoroethylene |
| No. | Name | Specification | Replacement cycle |
|---|---|---|---|
| 1 | Torch | Quartz torch | Clean and maintain once every 3 months.Service life 2 years |
| 2 | Nebulizer | Import GE nebulizer | Non-human damage over 3 years |
| 3 | Spray chamber | Double-tube spray chamber | Non-human damage over 3 years |
| 4 | Peristaltic Pump Head Hose | Injection and Drain Tubing | 3 Months |
| 5 | High- frequency coil | Silver-plated, three-turn coil | One year |
| 6 | Filter element | PP cotton material | Half a year |
Ordering and configuration
Final specifications, included accessories, consumables, software, certifications, power requirements, installation, warranty, and regulatory availability depend on the selected model and destination. Contact Scientific China to confirm the suitable configuration, minimum order quantity, price, lead time, documentation, and international delivery terms before purchase.
Reviews (0)
Only logged in customers who have purchased this product may leave a review.

































Reviews