Shipping Countries: United States (US)
Drawell DW-W4 Optical Emission Spectrometers (Arc/Spark-OES) Economical and Easy Metal Analyzer
Available in stock
The Drawell DW-W4 Optical Emission Spectrometers (Arc/Spark-OES) Economical and Easy Metal Analyzer is a professional analytical laboratory instrument. Review features and technical specifications, then request configuration, MOQ, lead time, warranty, and a formal quotation.
Scientific China
Store
Scientific China
StorePeople Also Viewed
-
RayKol Vitae 60 PCR Setup Automatic System — Estimated Price US$25,000–US$65,000
-
RayKol Vitae M96S Semi-Automatic Liquid Handling Workstation — Estimated Price US$18,000–US$45,000
-
RayKol EVA Mini 96 96-Well Plate Sample Drier — Estimated Price US$8,000–US$22,000
-
RayKol SAP 20 Automatic Dried Blood Spot Puncher — Estimated Price US$15,000–US$40,000
-
RayKol Mini Lids Automatic Capping Machine — Estimated Price US$6,000–US$18,000
-
Sineo ECH-II Temperature-Controlled Heating Block
| Product Category | Spectrophotometer > Full Spectrum Direct Reading Spectrometer |
|---|
Product Enquiry
Description
Drawell DW-W4 Optical Emission Spectrometers (Arc/Spark-OES) Economical and Easy Metal Analyzer
Product overview
DW-W4 Optical Emission Spectrometer is the most suitable instrument for the determination of various elements in different matrices (Fe, Cu, Al, Ni, Co, Mg, Ti, Zn, Pb, Sn, Ag, etc). It is an economical and easy solution for quick analysis near the furnace, metal material quality analysis, research laboratories, and metal grade identification.
The Drawell DW-W4 Optical Emission Spectrometers (Arc/Spark-OES) Economical and Easy Metal Analyzer supports research, pharmaceutical, environmental, food, industrial, and quality-control laboratories. Scientific China provides model selection, configuration review, export coordination, and formal quotations.
Key features
- Notes: The Buyer knows and agrees that the Seller may adjust the supply when the production of the above-mentioned instruments, spare parts and other suppliers change due to technological progress, product upgrading, market changes, etc.
- The instrument is calibrated with limited standard samples which Chongqing Drawell Instrument Co., Ltd. have for general purpose. For special alloy and special elements, the instrument must be calibrated by customer themselves. Or if customer is willing to provide sample collaboration for program development, the customer must provide accurate sample element content tables and ensure sample uniformity, but such curves are not used as acceptance indicators of the instrument.
- The DW-W4 optical emission spectrometer has a number of patented technologies that enable rapid determination of elements in metallic materials. The optical system uses a CMOS detector with a spectral range covering all typical materials. It is accurate and reliable for analysis from low-level elements to high-level elements. For different materials and different requirements, the cost-effective full-spectrum direct reading spectrometer can meet the requirements of metal manufacturing, processing industry and…
- 1. Optical system with superior performance
- The Paschen-Longge structure concave grating, full spectrum coverage, meets the customer’s need for full element detection.
- Direct optical technology and use optics made with MgF materials ensure optimum performance in the UV region.
- High resolution multi-CMOS readout system, lower dark current, better detection limit, higher stability, stronger sensitivity, meet N analysis requirements.
- 2. Large energy digital spark light source
- Fully digital intelligent composite light source DDD technology brings superior analytical performance.
- The compact design and semiconductor control technology make the light source more stable and more reliable.
- High-energy pre-combustion technology(HEPS), spark parameter adjustment, fully meet the excitation requirements of different substrates, different samples and different analytical elements.
- 3. Humanized sample spark stand design
- The spark stand directly introduces the spark light into the optical system
- Open sample stage for large sample testing requirements.
Applications
- Quantitative or qualitative laboratory analysis
- Research, method development, and routine quality control
- Application-specific testing with suitable accessories and methods
Technical specifications
| No. | Item | Specifications | QTY | Unit | Remarks |
|---|---|---|---|---|---|
| 1 | Optical Emission Spectrometer | DW-W4 | 1 | Set | Include in quotation. |
| 2 | Business computer | 1 | Set | ||
| 3 | Printer | 1 | Set | ||
| 4 | Tungsten electrode | 1 | Pc | ||
| 5 | Electrode pressure spring | 1 | Pc | ||
| 6 | The electrode fixed screw | 2 | Pcs | ||
| 7 | Electrode brush | Φ6 | 2 | Pcs | |
| 8 | Lens holder sealing ring | Φ16×2.65 | 2 | Pcs | |
| 9 | Lens holder sealing ring | Φ72×2.65 | 1 | Pc | |
| 10 | Exhaust gas filter core | 1 | Pc | ||
| 11 | Degreasing cotton | 15 | G | ||
| 12 | Power socket | 1 | Pc | ||
| 13 | M2 Internal hexagonal wrench | 1 | Set | ||
| 14 | M4 Internal hexagonal wrench | 1 | Set | ||
| 15 | Long handle phillips screwdriver | 1 | Pc | ||
| 16 | 13-15 fixed wrench | 1 | Pc | ||
| 17 | Spark machine screw | M6 | 4 | Pcs | |
| 18 | Fuse | 10A | 2 | Pcs | |
| 19 | Argon gas pressure reducing valve | 1 | Pc | ||
| 20 | Argon gas pipeline | 2 | M | ||
| 21 | Exhaust pipe | 1 | Pc | ||
| 22 | Gas bottle | 2 | Pcs | ||
| 23 | Print paper | 1 | Pc | ||
| 24 | Spectrometer manual | 1 | Set |
| Optional item | Qty | Note |
|---|---|---|
| High purity argon gas (pure ≧ 99.999%) | 1 bottle | Should prepare by customer. If can’t get should use argon purifier to get 99.999% argon gas. |
| Small air conditioning | 1 set | Essential, customer should prepare by themselves. |
| High precision magnetic saturation voltage stabilizer (1KVA) | 1 set | Need for voltage instability, if the customer uses intermediate frequency furnace, then need 3KVA Voltage Stabilizer |
| Argon purifier | 1 set | When argon gas is not as pure as 99.999%. |
| Samples grinder (ferrous metals) or Mini lathe (non-ferrous metals) | 1 set | Essential |
| Type samples | pieces | Essential for foundry |
| The analysis ranges and elements of Al base | |||||||
|---|---|---|---|---|---|---|---|
| Al-000 | Al-001 | Al-002 | Al-003 | Al-004 | Al-005 | ||
| No. | Elements | Global Program | Al Low Alloy | Al-Si Alloy | Al-Zn Alloy | Al-Cu Alloy | Al-Mg-Si Alloy |
| 1 | Si | 0.01-24 | 0.01-1.63 | 0.02-24 | 0.02-9.4 | 0.02-7 | 0.02-2.3 |
| 2 | Fe | 0.01-4 | 0.01-1.65 | 0.02-4 | 0.03-1 | 0.05-1.9 | 0.07-0.80 |
| 3 | Cu | 0.002-13 | 0.002-1 | 0.005-6 | 0.01-4.3 | 0.01-13 | 0.07-1 |
| 4 | Mn | 0.001-2.4 | 0.001-1 | 0.005-1 | 0.02-1 | 0.05-1 | 0.03-2.4 |
| 5 | Mg | 0.002-10.2 | 0.002-1 | 0.01-1.5 | 0.01-4 | 0.01-2.7 | 0.006-10.2 |
| 6 | Cr | 0.001-0.5 | 0.001-0.15 | 0.005-0.5 | 0.01-0.4 | 0.01-0.14 | 0.01-0.4 |
| 7 | Ni | 0.001-2.5 | 0.001-0.16 | 0.02-2.5 | 0.01-0.2 | 0.01-2.3 | 0.005-0.25 |
| 8 | Zn | 0.002-12 | 0.002-0.5 | 0.005-3.5 | 0.01-12 | 0.05-3.5 | 0.01-1 |
| 9 | Ti | 0.001-0.4 | 0.001-0.15 | 0.005-0.4 | 0.005-0.3 | 0.001-0.2 | 0.007-0.3 |
| 10 | Cd | 0.001-0.3 | 0.01-0.3 | 0.001-0.3 | 0.002-0.3 | 0.01-0.3 | 0.01-0.3 |
| 11 | Pb | 0.001-0.5 | 0.02-0.5 | 0.005-0.5 | 0.005-0.5 | 0.01-0.5 | 0.001-0.5 |
| 12 | Sb | 0.005-0.4 | 0.005-0.4 | ||||
| 13 | Sn | 0.005-0.5 | 0.01-0.2 | 0.003-0.5 | 0.005-0.2 | 0.02-0.3 | 0.007-0.2 |
| 14 | Sr | 0.005-0.1 | 0.005-0.1 | ||||
| 15 | V | 0.002-0.2 | 0.004-0.05 | 0.005-0.2 | 0.005-0.03 | 0.01-0.03 | 0.002-0.03 |
| 16 | Zr | 0.001-0.3 | 0.001-0.12 | 0.005-0.2 | 0.01-0.3 | 0.001-0.2 | 0.003-0.12 |
| 17 | p | 0.002-0.005 | 0.002-0.005 | ||||
| 18 | Al | Reference | Reference | Reference | Reference | Reference | Reference |
| No. | Elements | Brass |
|---|---|---|
| 1 | Zn | 0.5-43.0 |
| 2 | Pb | 0.01-6.0 |
| 3 | Sn | 0.009-4.8 |
| 4 | P | 0.002-0.14 |
| 5 | Mn | 0.001-5.3 |
| 6 | Fe | 0.02-3.0 |
| 7 | Ni | 0.009-1.8 |
| 8 | Si | 0.001-4.6 |
| 9 | Mg | 0.001-0.01 |
| 10 | Cr | 0.001-0.2 |
| 11 | Co | 0.004-0.1 |
| 12 | Al | 0.001-6.7 |
| 13 | S | 0.001-0.15 |
| 14 | Cu | Reference |
| Item | Index | |
|---|---|---|
| Optical System | Focal Length | 350mm |
| Wavelength range | 165nm-589nm(extendable) | |
| Detector | High resolution CMOS Multi detectors | |
| Light chamber | Argon cycle filling | |
| Pixel resolution | 30pm | |
| Grating line | 3600m1/mm | |
| First order spectral line dispersion rare | 1.2nm/mm | |
| Average resolution ratio | 10pm/pixel | |
| Full spectrum | ||
| Light chamber temperature is controlled automatically | ||
| Spark Source | Type | Digital arc and spark source |
| Spark frequency | 100-1000HZ | |
| Discharge current | 1-400A | |
| Ignition voltage | >15000V | |
| Excitation light | Optimization of discharge parameters design | |
| High energy precombustion technology HEPS | ||
| Processor | High-speed data synchronization acquisition and processing | |
| Spark Stand | Electrode | Tungsten electrode technology |
| Make up | Thermal deformation self-compensation design | |
| Argon flushed with minimal consumption of Argon | ||
| Spray discharge electrode technology | ||
| Adjustable electrode technology | ||
| Others | Measurable elements | Fe、Al、Cu、Ni、Ti、Co、Zn、Sn、Mg、Pb etc |
| Dimension | 714mm(L)*558mm*270mm(H) | |
| weight | About 40kg | |
| Storage temperature | 0℃-45℃ | |
| Operating temperature | 10℃-35℃, 23±2℃ is recommended | |
| Power | AC220V/50Hz(Customized) | |
| Power consumption | Excitation:400W/Stand by:50W | |
| Argon quality | 99.999%, Argon pressure>4Mpa | |
| Argon consumption | 5L/min during spark mode | |
| Interface | Ethernet data transmission based on DM9000A |
Ordering and configuration
Final specifications, included accessories, consumables, software, certifications, power requirements, installation, warranty, and regulatory availability depend on the selected model and destination. Contact Scientific China to confirm the suitable configuration, minimum order quantity, price, lead time, documentation, and international delivery terms before purchase.
Reviews (0)
0.0
Review this product
Share your thoughts with other customers
Only logged in customers who have purchased this product may leave a review.































Reviews
There are no reviews yet.