Drawell DW-CIC-D160 Ion Chromatography
Available in stock
The Drawell DW-CIC-D160 Ion Chromatography is a professional analytical laboratory instrument. Review features and technical specifications, then request configuration, MOQ, lead time, warranty, and a formal quotation.
Scientific China
Store| Product Category | Chromatography > Ion Chromatography |
|---|
Product Enquiry
Description
Drawell DW-CIC-D160 Ion Chromatography
Product overview
The DW-CIC-D160 Ion Chromatography is designed for sensitive and flexible analysis of inorganic anions, cations and other ionic compounds. Its built-in eluent generator automatically prepares eluent online from ultrapure water, reducing manual preparation and supporting gradient elution.
The Drawell DW-CIC-D160 Ion Chromatography supports research, pharmaceutical, environmental, food, industrial, and quality-control laboratories. Scientific China provides model selection, configuration review, export coordination, and formal quotations.
Key features
- Built-in eluent generator—0.1-100 mM, free from configuring eluent, with gradient elution available.
- Modular manufacturing process to maintain excellent systemic stability.
- Built-in low-pressure degassing technology to eliminate bubble interference for more stability.
- Work across a variety of detectors, to expand the scope of applications of ion chromatography.
- Atmospheric composition (dust, particulate matter, fog, acid gas), acid rain, water quality analysis
- Contaminated ingredients, additives, inherent ingredients, adulteration, production process monitoring
- Pesticide, fertilizer, soil, feed, food, plant analysismaterials in food
- Blood, urine, infusion composition, clinical examination, human trace element analysis
- Protein separation and purification
- Analysis of plant medicinal materials, mineral medicinal ingredients, and preparation ingredients
- Metal materials, semiconductor materials, surface treatment, ultrapure water analysis
- Raw material analysis, product quality control, electrolytic plating solution analysis, papermaking
- Analysis of cosmetics, detergents, cleaning agents, raw materials, and product components
- 1. Clean Water Samples
Applications
- Quantitative or qualitative laboratory analysis
- Research, method development, and routine quality control
- Application-specific testing with suitable accessories and methods
Technical specifications
| Built-in Eluent | Eluent Types | KOH/NaOH/LiOH/MSA |
|---|---|---|
| Generator | Eluent Concentration Range | 0.1-100mM |
| Concentration Increment | 0.1mM | |
| Flow Rate Range | 0.1-5.0mL/min | |
| Maximum Pressure | 30MPa | |
| Minimum Pressure | 5MPa | |
| Accuracy of Gradient | 0.15% | |
| Vacuum degasser | Vacuum degree | -70kPa |
| Internal Volume | 300μL | |
| Maximum Flow Rate | 10mL/min | |
| degassing efficiency | 1.0mL/min 90% | |
| degassing volume | 7.5mL | |
| Flow Path | PEEK material | Chemically inert, metal-free PEEK flow paths, compatible with aqueous eluents of pH 0-14 and reversed-phase solvents |
| Pump | Type | High-pressure and low-pulse two-piston tandem advection pump |
| Maximum Pressure | 42MPa | |
| Flow Range | 0.001~9.999mL/min | |
| Pressure Pulse | ≤0.5% | |
| Flow Precision | ≤0.1% | |
| Flow Accuracy | ≤0.1% | |
| External Diameterof the Tube | 1/16″ | |
| Valve | Contact Material of the Rotor | PEEK |
| Control Mode | By Stepper motor | |
| Power Supply | 24V (DC) | |
| Column Heater | Operating Temperature Range | Ambient + 5 to 60 ℃ |
| Controlling Temperature Accuracy | ±0.1℃ | |
| Temperature Stability | ≤0.1℃/h | |
| Columns Supported | 2, 3, 4 and 5 mm i.d. Maximum length 250 mm analytical column with 50 mm guard column. | |
| Conductivity Detector | Type | Auto-range conductivity detector |
| Cell Volume | ≤0.8μL | |
| Detection Range | 0~50000μS/cm | |
| Resolution | ≤0.0020nS/cm | |
| Output Voltage | -6000~+6000mv(adjustable) | |
| Electronic Noise | 0.02nS | |
| Baseline Noise | ≤0.0005μS/cm | |
| Baseline Drift | ≤0.005μS | |
| Operating Temperature Range | Ambient +5℃~60℃ | |
| Controlling Temperature Accuracy | ±0.01℃ | |
| Temperature Compensation | 1.7 %/℃ | |
| Maximum Pressure | 10.0MPa | |
| Instrument Linearity | ≥0.999 | |
| Quantitative Repeatability | ≤0.5% | |
| Qualitative Repeatability | ≤0.2% | |
| Minimum Detectable Concentration | Cl-≤0.0003ug/mL Li+≤0.0001ug/mL | |
| Suppressor | Type | Self-Regeneration electrolytic micro-membrane suppressor |
| MaximumPressure | 6.0MPa | |
| Non-Suppressed Chromatography | Yes/support | |
| Void Volume | <40μL (4mm) <15μL (2mm) | |
| Power Supply | 150W | |
| External Size(L*W*H*) | 350*480*580 (mm) | |
| Net Weight(KG) | 34 | |
| Gross Weight(KG) | 40 |
Ordering and configuration
Final specifications, included accessories, consumables, software, certifications, power requirements, installation, warranty, and regulatory availability depend on the selected model and destination. Contact Scientific China to confirm the suitable configuration, minimum order quantity, price, lead time, documentation, and international delivery terms before purchase.
Reviews (0)
Only logged in customers who have purchased this product may leave a review.




































Reviews