Drawell Automatic Kjeldahl Analyzer with Distillation and Titration DW-K9860
Product overview
DW-K9860 Automatic Kjeldahl Analyzer is an automatic device integrating distillation and titration functions designed based on classic Kjeldahl nitrogen determination method . It’s equipped with the latest core control system, powerful automatic degree and high-quality components, can easily achieve automatic cleaning of digestion tubes and titration cups, control steam supply and have real-time detection of condensation temperature. High-accuracy charging pump and titration system ensure test results accuracy, and multiple fluid level detection gives a smooth test process.
The Drawell Automatic Kjeldahl Analyzer with Distillation and Titration DW-K9860 supports research, pharmaceutical, environmental, food, industrial, and quality-control laboratories. Scientific China provides model selection, configuration review, export coordination, and formal quotations.
Key features
- High accuracy dozing and working: adopt 4 KNF pumps work for dozing, measurement liquid volume.
- Easy Maintenance: Pre-install functions of cleaning, including receiving cup cleaning, alkali pipeline cleaning, boric acid pipeline cleaning, acid washing, and steam bottle evacuation. support customer to make the routine maintenance easily.
- High titration accuracy, up to 2.0μL/step.
- Integrated printer on the instruments.
- Automatic cleaning ensure operator safety and save time.
- External titration cup design gives operator real-time control of the whole test process.
- Steam flow is controllable, satisfying different test requirements.
- Regent barrel enjoys fluid absence warning function, ensuring smooth test going.
- High-precision charging pump and titration ensure test results accuracy.
- The temperature of distilled liquid is detected real time. If the temperature of distilled liquid is abnormal, to ensure the accuracy of experiment’s result, instrument will stop working.
- There is no automatic endpoint detection; judgment relies on color change of boric acid absorbing solution. Continue distilling for 5–10 minutes after the absorbing solution turns from purplish red to blue-green. Lift the condenser tube out of the liquid surface and distill for another 2 minutes to wash residual ammonia on the tube wall and avoid low results. Extend distillation time for samples high in protein and fat.
- Inconsistent manual addition of alkali solution in each test, leading to variable ammonia release;
- Unstable steam supply due to fluctuating heating flame;
- Large human visual error as the titration endpoint is judged by naked eyes;
Applications
- Food and Agricultural Product Testing
- Feed Industry Quality Control
- Agricultural and Environmental Monitoring
- Pharmaceutical and Chemical Research
Technical specifications
| Measuring range | 0.1mg ~200mg N |
|---|---|
| Analysis time | 5~10min/sample |
| Reproducibility | Average value relative error ±0.5% |
| Recovery | ≧99.5% |
| Burette volume | 2.0μL/step |
| Sample capacity | solid≦5g/sample, liquid≦20mL/sample |
| Water consumption in the distillation process | 1.5L/min |
| Data storage capacity | 1000 groups |
| Power supply | 220VAC±10%, 50Hz |
| Power | 2Kw |
| Net weight | 38Kg |
| Dimensions | 455mm×391mm×730mm |
| Item | K1100F | K9860 | K9840 |
|---|---|---|---|
| Automatic | Y | Y | N |
| Measuring range | 0.1mg~200mg N | 0.1mg~200mg N | 0.1mg~240mg N |
| Reproducibility | Average value relative error±0.5% | Average value relative error±0.5% | Average value relative error±0.5% |
| Recovery | ≥99.5% | ≥99.5% | ≥99.5% |
| Sample capacity | solid 5g/sample, liquid 20mL/sample | solid 5g/sample, liquid 20mL/sample | solid 5g/sample, liquid 20mL/sample |
| Water consumption in the distillation process | 1.5L/min | 1.5L/min | 1.5L/min |
| Data storage | 1800 groups | 1000 groups | — |
| Burette volume | 1.0μL/step | 2.0μL/step | — |
| Analysis time | 3-8min/sample | 5~10min/sample | — |
| Power supply | 220VAC±10%, 50/60Hz | 220VAC±10%, 50/60Hz | 220VAC±10%, 50/60Hz |
| Power | 2KW | 2KW | 1.3KW |
| Function | K1100F | K9860 | K9840 |
|---|---|---|---|
| Steam Flow Adjustment | Y | Y | N |
| Steam model | Y | N | N |
| Digestion tube discharge | Y | N | N |
| Digestion tube cleaning | Y | N | N |
| Reagents bottle liquid level monitor | Y | N | N |
| Receiving cup cleaning | Y | Y | – |
| Burette calibration | Y | Y | – |
| Data output | Y (optional) | N | N |
| Method storage | Y | Y | N |
| Boric acid pipeline cleaning | Y | Y | N |
| Alkali pipeline cleaning | Y | Y | Y |
| Safety Door | Y | Y | Y |
| Digestion tube on position monitor | Y | N | Y |
| Condensing water flow monitor | Y | Y | Y |
| Water level monitor | Y | Y | Y |
| Steam generator temperature overload protection | Y | Y | Y |
| Steam generator pressure overload protection | Y | N | N |
| Liquid level monitor for Alkali/ acid/ Distilled water bottle | Y | N | N |
Ordering and configuration
Final specifications, included accessories, consumables, software, certifications, power requirements, installation, warranty, and regulatory availability depend on the selected model and destination. Contact Scientific China to confirm the suitable configuration, minimum order quantity, price, lead time, documentation, and international delivery terms before purchase.