Shipping Countries: United States (US)
BIOBASE Double-side Class II A2 Biological Safety Cabinet | Estimated Price: US$3,000–6,000 | Request a Quote
Available in stock
Biosafety cabinet is a box-type air purification negative pressure safety device that can prevent the aerosol escape of some dangerous or unknown biological particles in the process of experimental operation.
Estimated equipment price only. Shipping, import duties, installation, and logistics are additional and vary by destination and shipping method. We will contact you to confirm the total cost before processing your order.
Scientific China
StorePeople Also Viewed
-
SonoStar 3CL 2in1 palm doppler ultrasound scanner — Estimated US$1,610
-
SonoStar 4CR biplane rectal palm doppler ultrasound scanner — Estimated US$2,400
-
SonoStar 4T transvaginal palm doppler ultrasound scanner — Estimated US$1,800
-
SonoStar 4T transvaginal palm doppler ultrasound scanner — Estimated US$1,800
-
SonoStar 4PA phased array palm doppler ultrasound scanner — Estimated US$1,800
-
SonoStar 4M micro-convex palm doppler ultrasound scanner — Estimated US$1,800
| Product Category | Air Protection Products > Biological Safety Cabinet |
|---|
Product Enquiry
Description
Biosafety cabinet is a box-type air purification negative pressure safety device that can prevent the aerosol escape of some dangerous or unknown biological particles in the process of experimental operation. It is widely used in scientific research, teaching, clinical testing and production in the fields of microbiology, genetic engineering and biological products, and is the most basic safety protection equipment in the first-level protective barrier of laboratory biosafety.
Technical specifications
Features:
1. 7-inch large touch color display: touch operation, real-time and clearer display of various values of the safety cabinet, dynamic air flow pattern diagram, fault alarm sound and light prompt.
2. The power-on password can be set to prevent mis-operation by irrelevant personnel.
3. Automatically adjust the wind speed.
4. Power-failure memory, restore the state before power-failure, and have a visual reminder to alarm.
5. Interlocking function: UV lamp and front window; UV lamp and fan; fan and front window.
6. It has an appointment timing function, which can automatically set the timing of turning on, turning off and the running time of the UV lamp, fan, and socket.
|
Model |
BSC-1500IIA2-S |
|
External Size(W*D*H) |
1500*785*2220mm |
|
Internal Size(W*D*H) |
1160*700*660mm |
|
Tested Opening |
Safety height 200mm |
|
Max Opening |
450mm |
|
Inflow Velocity |
0.48±0.025m/s |
|
Downflow Velocity |
0.33±0.025m/s |
|
ULPA Filter |
Two, 99.9995% efficiency at 0.12μm, filter life indicator |
|
Front Window |
Two-layer laminated toughened glass≥5mm. Anti UV. |
|
Noise |
≤67dB |
|
UV Lamp |
15W*2 UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination |
|
LED Lamp |
16W*2 |
|
Illumination |
≥1000Lux |
|
Consumption |
1300W |
|
Socket |
Two, total consumption: 500W |
|
Display |
LCD display |
|
Control System |
70% air recirculation, 30% air exhaust |
|
Visual and Audio Alarm |
Filter replacement, window over height, abnormal air flow velocity; High filter pressure alarm |
|
Material |
Work Zone: 304 stainless steel Main Body: Cold-rolled steel with anti-bacteria powder coating |
|
Work Surface Height |
750mm with base stand |
|
Power Supply |
AC220V, 50/60Hz; 110V, 60Hz |
|
Standard Accessory |
Cabinet*1, Base stand*1, Fan*1, Supply filter*1, Exhaust filter*1, LED lamp*2, UV lamp*2, Drain ball valve*1, Socket*2 |
|
Optional Accessory |
Arm rest, Formalin fumigation sterilizer, Infrared sterilizer, S.S. water tap, S.S. gas tap |
|
Package Size(W*D*H) |
1770*930*1850mm |
|
Gross Weight |
325kg |
Reviews (0)