Shipping Countries: United States (US)
Novel Optics Plan-Achromatic Objective — Estimated US$100
$100.00
Available in stock
The plan-achromatic objective family provides flat-field imaging for routine biological microscopy. N-PLN and N-iPLN families; Brightfield, phase-contrast, darkfield and Hoffman configurations listed.
Estimated equipment price only. Shipping, import duties, installation, and logistics are additional and vary by destination and shipping method. We will contact you to confirm the total cost before processing your order.
Scientific China
StorePeople Also Viewed
-
Sciway W-P 99.9999% High-Purity GC Nitrogen Generator — US$18,500
$18,500.00
-
Sciway Centralized LC-MS Gas Supply System — US$15,000
$15,000.00
-
Sciway XA Series LC-MS Nitrogen Generator — US$12,000
$12,000.00
-
Sciway UTAB Series LC-MS Nitrogen Generator — US$12,000
$12,000.00
-
Sciway BIO Series Multi-Instrument LC-MS Nitrogen Generator — US$21,000
$21,000.00
-
Sciway Y-CAD Nitrogen Generator for CAD and ELSD — US$9,000
$9,000.00
| Manufacturer | Ningbo Yongxin Optics Co., Ltd. (Novel Optics) |
|---|---|
| Model / Product Family | Plan-Achromatic Objective |
Product Enquiry
Description
The plan-achromatic objective family provides flat-field imaging for routine biological microscopy.
Technical details and specifications
- N-PLN and N-iPLN families
- Brightfield, phase-contrast, darkfield and Hoffman configurations listed
- Magnification and numerical aperture vary by code
- Dry, water and oil-immersion variants are not interchangeable
Manufacturer configuration tables
| Application | Objective | NA | W.D.(mm) | Cover-glass Thickness | Correction Ring | Spring-loaded | Bright-field | Dark-field | DIC | Phase Contrast | Polarization | Hoffman Phase Contrast | Fluorescence | |||
| Visible | UV | NIR | ||||||||||||||
| Bright-field | N-PLN | 2× | 0.06 | 9 | – | ◎ | △ | ○ | ||||||||
| 4× | 0.1 | 30 | – | ◎ | △ | ○ | ||||||||||
| 10× | 0.25 | 10.2 | – | ◎ | △ | ○ | ||||||||||
| 20× | 0.4 | 13.36 | 0.17 | ◎ | ○ | △ | ○ | |||||||||
| 40× | 0.65 | 0.7 | 0.17 | √ | ◎ | ○ | △ | ○ | ||||||||
| 50× Oil | 0.95 | 0.17 | √ | ◎ | ○ | △ | ○ | |||||||||
| 60× | 0.8 | 0.17 | √ | ◎ | ○ | △ | ○ | |||||||||
| 100× Oil | 1.25 | 0.22 | 0.17 | √ | ◎ | △ | ○ | |||||||||
| N-iPLN | 4× | 0.1 | 29.3 | 1.2 | ◎ | △ | ○ | |||||||||
| 10× | 0.25 | 9.5 | 1.2 | ◎ | △ | ○ | ||||||||||
| 20× | 0.4 | 4 | 1.2 | ◎ | △ | ○ | ||||||||||
| 40× | 0.6 | 2.3 | 1.2 | ◎ | △ | ○ | ||||||||||
| Phase Contrast | N-PLN PH | 10× Ph | 0.25 | 10.2 | – | ○ | ◎ | △ | △ | |||||||
| 20× Ph | 0.4 | 13.36 | 0.17 | ○ | ○ | ◎ | △ | △ | ||||||||
| 40× Ph | 0.65 | 0.7 | 0.17 | √ | ○ | ○ | ◎ | △ | △ | |||||||
| 100× Ph Oil | 1.25 | 0.22 | 0.17 | √ | ○ | ◎ | △ | △ | ||||||||
| N-iPLN PH | 10× Ph | 0.25 | 9.5 | 1.2 | ○ | ◎ | △ | △ | ||||||||
| 20× Ph | 0.4 | 4 | 1.2 | ○ | ◎ | △ | △ | |||||||||
| 40× Ph | 0.6 | 2.3 | 1.2 | ○ | ◎ | △ | △ | |||||||||
| Dark-field | N-PLN BF | 100× | 0.50-1.25 | 0.17 | √ | ◎ | ◎ | △ | ○ | |||||||
| Hoffman Phase Contrast | N-iPLN H | 10X | 0.25 | 9.5 | 1.2 | ○ | △ | ◎ | △ | |||||||
| 20X | 0.4 | 4 | 1.2 | ○ | △ | ◎ | △ | |||||||||
| 40X | 0.6 | 2.3 | 1.2 | ○ | △ | ◎ | △ | |||||||||
Configuration and ordering
Reference configuration: one 10× N-PLN-class plan-achromatic objective; exact code to be confirmed.
The title shows a rounded estimate based on a public dealer reference. Confirm the current version, objective set and included accessories before ordering.
Manufacturer product information
Buying questions answered
Is the price for one objective or the full illustrated set?
The reference estimate is for one 10× N-PLN-class plan-achromatic objective; exact code to be confirmed. Product-family photographs may show several objectives; those are alternatives, not an included set.
Will this objective fit my existing microscope?
Confirm the exact objective code, thread, parfocal distance, tube-lens focal length, correction medium and coverslip or vessel-bottom thickness. A matching thread alone does not establish optical compatibility.
Which optical parameters should be selected?
N-PLN and N-iPLN families; Brightfield, phase-contrast, darkfield and Hoffman configurations listed; Magnification and numerical aperture vary by code. Select numerical aperture, working distance, immersion medium and contrast mode using the exact objective code; do not transfer specifications between variants.
What power supply and installation are required?
Confirm the delivered power-supply input range, frequency, plug and electrical labels for the destination. Bench space, computer requirements, alignment, installation and operator training must be agreed for the selected configuration; a universal voltage specification is not assumed.
What does the estimated price exclude?
Shipping, import duties, installation and logistics are additional. Optional optics, accessories, software licenses, engineering and integration are separate unless expressly included. The final configuration and total cost will be confirmed before processing the order.
What are the warranty and after-sales arrangements?
A fixed warranty term or local on-site service package has not been verified for this supply route. The written offer must state coverage, parts and labor, remote support, repair location and responsibility for return freight.
What is the lead time and is stock available?
Current stock, production time and delivery date require confirmation for the chosen configuration, quantity and destination. No fixed dispatch or delivery promise is made in this listing.
Reviews (0)
Only logged in customers who have purchased this product may leave a review.








Reviews
There are no reviews yet.