Shipping Countries: United States (US)
Novel Optics Objective Lenses — Estimated US$4,500
Available in stock
Novel Optics supplies objective-lens families for biological, industrial, fluorescence and OEM microscopy systems. TIRF, silicone-oil, plan-apochromatic, NIR and semi-apochromatic families; TIRF 100× oil objective: NA 1.49.
Estimated equipment price only. Shipping, import duties, installation, and logistics are additional and vary by destination and shipping method. We will contact you to confirm the total cost before processing your order.
Scientific China
StorePeople Also Viewed
-
Novel Optics Plan-semi-apochromatic Objective — Estimated US$1,100
-
Novel Optics Plan-apochromatic Objective — Estimated US$2,200
-
Novel Optics NGI-6 Gemological Microscope — Estimated US$2,200
-
Novel Optics NX600 Industrial-Inspection Microscope — Estimated US$12,000
-
Novel Optics Tube-lens Assembly — Estimated US$450
-
Novel Optics Stand Frame — Estimated US$700
$700.00
| Manufacturer | Ningbo Yongxin Optics Co., Ltd. (Novel Optics) |
|---|---|
| Model / Product Family | Objective Lenses |
Product Enquiry
Description
Novel Optics supplies objective-lens families for biological, industrial, fluorescence and OEM microscopy systems.
Technical details and specifications
- TIRF, silicone-oil, plan-apochromatic, NIR and semi-apochromatic families
- TIRF 100× oil objective: NA 1.49
- TIRF working distance listed: 0.09–0.16 mm
- 25× silicone-oil objective: NA 1.05; working distance 0.5–0.6 mm
- Exact specifications depend on objective code
Manufacturer configuration tables
| Application | Objective | NA | W.D.(mm) | Cover-glass Thickness | Correction Ring | Spring-loaded | Bright-field | Dark-field | DIC | Phase Contrast | Polarization | Fluorescence | |||
| Visible | UV | NIR | |||||||||||||
| Super Resolution/Confocal Imaging | N-PLAPO | 10× | 0.45 | 4 | 0.17 | ◎ | △ | ○ | ○ | ||||||
| 20× | 0.75 | 1.1 | 0.17 | ◎ | ○ | △ | ○ | ○ | |||||||
| 20× | 0.8 | 0.9 | 0.17 | ◎ | ○ | △ | ○ | ○ | |||||||
| 40× C | 0.95 | 0.19-0.21 | 0.11-0.23 | √ | ◎ | ○ | △ | ○ | ○ | ||||||
| 60× Oil | 1.4 | 0.25 | 0.17 | √ | ◎ | ○ | △ | ○ | ○ | ||||||
| 100× Oil | 1.45 | 0.13 | 0.17 | √ | ◎ | △ | ○ | ○ | |||||||
| 20×C WI | 0.95 | 1.1 | 0.11-0.23 | ◎ | △ | ○ | ○ | ||||||||
| 25×C Sil | 1.05 | 0.5-0.6 | 0.11-0.23 | √ | ◎ | △ | ○ | ○ | |||||||
| Application | Objective | NA | W.D.(mm) | Cover-glass Thickness | Correction Ring | Spring-loaded | Bright-field | Dark-field | DIC | Phase Contrast | Polarization | Fluorescence | |||
| Visible | UV | NIR | |||||||||||||
| Electrophysiology | N-PLAPO NIR | 10× W NIR | 0.3 | 3.5 | 0 | ◎ | △ | ○ | ○ | ◎ | |||||
| 40× W NIR | 0.8 | 3.5 | 0 | ◎ | △ | ○ | ○ | ◎ | |||||||
| Application | Objective | NA | W.D.(mm) | Cover-glass Thickness | Correction Ring | Spring-loaded | Bright-field | Dark-field | DIC | Phase Contrast | Polarization | Fluorescence | |||
| Visible | UV | NIR | |||||||||||||
| Bright-field | N-PLFN | 4× | 0.13 | 17 | – | ◎ | △ | ◎ | ◎ | ||||||
| 10× | 0.3 | 15.8 | 0.17 | ◎ | ○ | △ | ◎ | ◎ | |||||||
| 20× | 0.5 | 2.7 | 0.17 | ◎ | ○ | △ | ◎ | ◎ | |||||||
| 40× | 0.75 | 1.35 | 0.17 | √ | ◎ | ○ | △ | ◎ | ◎ | ||||||
| 100× | 1.4 | 0.18 | 0.17 | √ | ◎ | △ | ◎ | ◎ | |||||||
| N-iPLFN | 4× | 0.13 | 16.2 | 1.2 | ◎ | △ | ◎ | ◎ | |||||||
| 10× | 0.3 | 15.7 | 1.2 | ◎ | △ | ◎ | ◎ | ||||||||
| 20× | 0.45 | 8 | 1.2 | ◎ | △ | ◎ | ◎ | ||||||||
| 40×W | 0.6 | 3.6 | 1.2 | ◎ | △ | ◎ | ◎ | ||||||||
| 20×C | 0.45 | 8.80-7.50 | 0-2.00 | √ | √ | ◎ | △ | ◎ | ◎ | ||||||
| 40×C | 0.6 | 4.40-3.00 | 0-2.00 | √ | √ | ◎ | △ | ◎ | ◎ | ||||||
| 60×C | 0.7 | 2.60-1.80 | 0.10-1.30 | √ | √ | ◎ | △ | ◎ | ◎ | ||||||
| Application | Objective | NA | W.D.(mm) | Cover-glass Thickness | Correction Ring | Spring-loaded | Bright-field | Dark-field | DIC | Phase Contrast | Polarization | Fluorescence | |||
| Visible | UV | NIR | |||||||||||||
| Phase Contrast | N-PLFN PH | 4×Ph | 0.13 | 17 | – | ○ | ◎ | △ | △ | ||||||
| 10×Ph | 0.3 | 15.8 | 0.17 | ○ | ○ | ◎ | △ | △ | |||||||
| 20×Ph | 0.5 | 2.7 | 0.17 | ○ | ○ | ◎ | △ | △ | |||||||
| 40×Ph | 0.75 | 1.35 | 0.17 | √ | ○ | ○ | ◎ | △ | △ | ||||||
| 100×Ph | 1.4 | 0.18 | 0.17 | √ | ○ | ◎ | △ | △ | |||||||
| N-iPLFN PH | 4×Ph | 0.13 | 16.2 | 1.2 | ○ | ◎ | △ | △ | |||||||
| 10×Ph | 0.3 | 15.7 | 1.2 | ○ | ◎ | △ | △ | ||||||||
| 20×Ph | 0.45 | 8 | 1.2 | ○ | ◎ | △ | △ | ||||||||
| 40×Ph | 0.6 | 3.6 | 1.2 | ○ | ◎ | △ | △ | ||||||||
| 20× C Ph | 0.45 | 8.80-7.50 | 0-2.00 | √ | √ | ○ | ◎ | △ | △ | ||||||
| 40×C Ph | 0.6 | 4.40-3.00 | 0-2.00 | √ | √ | ○ | ◎ | △ | △ | ||||||
| 60×C Ph | 0.7 | 2.60-1.80 | 0.10-1.30 | √ | √ | ○ | ◎ | △ | △ | ||||||
| Application | Objective | NA | W.D.(mm) | Cover-glass Thickness | Correction Ring | Spring-loaded | Bright-field | Dark-field | DIC | Phase Contrast | Polarization | Hoffman Phase Contrast | Fluorescence | |||
| Visible | UV | NIR | ||||||||||||||
| Bright-field | N-PLN | 2× | 0.06 | 9 | – | ◎ | △ | ○ | ||||||||
| 4× | 0.1 | 30 | – | ◎ | △ | ○ | ||||||||||
| 10× | 0.25 | 10.2 | – | ◎ | △ | ○ | ||||||||||
| 20× | 0.4 | 13.36 | 0.17 | ◎ | ○ | △ | ○ | |||||||||
| 40× | 0.65 | 0.7 | 0.17 | √ | ◎ | ○ | △ | ○ | ||||||||
| 50× Oil | 0.95 | 0.17 | √ | ◎ | ○ | △ | ○ | |||||||||
| 60× | 0.8 | 0.17 | √ | ◎ | ○ | △ | ○ | |||||||||
| 100× Oil | 1.25 | 0.22 | 0.17 | √ | ◎ | △ | ○ | |||||||||
| N-iPLN | 4× | 0.1 | 29.3 | 1.2 | ◎ | △ | ○ | |||||||||
| 10× | 0.25 | 9.5 | 1.2 | ◎ | △ | ○ | ||||||||||
| 20× | 0.4 | 4 | 1.2 | ◎ | △ | ○ | ||||||||||
| 40× | 0.6 | 2.3 | 1.2 | ◎ | △ | ○ | ||||||||||
| Application | Objective | NA | W.D.(mm) | Cover-glass Thickness | Correction Ring | Spring-loaded | Bright-field | Dark-field | DIC | Phase Contrast | Polariztion | Hoffman Phase Contrast | Fluorescence | |||
| Visible | 紫UV | NIR | ||||||||||||||
| Phase Contrast | N-PLN PH | 10× Ph | 0.25 | 10.2 | – | ○ | ◎ | △ | △ | |||||||
| 20× Ph | 0.4 | 13.36 | 0.17 | ○ | ○ | ◎ | △ | △ | ||||||||
| 40× Ph | 0.65 | 0.7 | 0.17 | √ | ○ | ○ | ◎ | △ | △ | |||||||
| 100× Ph Oil | 1.25 | 0.22 | 0.17 | √ | ○ | ◎ | △ | △ | ||||||||
| N-iPLN PH | 10× Ph | 0.25 | 9.5 | 1.2 | ○ | ◎ | △ | △ | ||||||||
| 20× Ph | 0.4 | 4 | 1.2 | ○ | ◎ | △ | △ | |||||||||
| 40× Ph | 0.6 | 2.3 | 1.2 | ○ | ◎ | △ | △ | |||||||||
| Dark-field | N-PLN BF | 100× | 0.50-1.25 | 0.17 | √ | ◎ | ◎ | △ | ○ | |||||||
| Hoffman Phase Contrast | N-iPLN H | 10X | 0.25 | 9.5 | 1.2 | ○ | △ | ◎ | △ | |||||||
| 20X | 0.4 | 4 | 1.2 | ○ | △ | ◎ | △ | |||||||||
| 40X | 0.6 | 2.3 | 1.2 | ○ | △ | ◎ | △ | |||||||||
Configuration and ordering
Reference configuration: one 100× NA 1.49 TIRF apochromatic oil-immersion objective.
The title shows an indicative budget estimate based on public market references and the selected configuration. It is not a confirmed Novel Optics quotation.
Photographs may show different configurations or optional accessories within this product family. Only items expressly listed in the confirmed order are included.
Manufacturer product information
Buying questions answered
Is the price for one objective or the full illustrated set?
The reference estimate is for one 100× NA 1.49 TIRF apochromatic oil-immersion objective. Product-family photographs may show several objectives; those are alternatives, not an included set.
Will this objective fit my existing microscope?
Confirm the exact objective code, thread, parfocal distance, tube-lens focal length, correction medium and coverslip or vessel-bottom thickness. A matching thread alone does not establish optical compatibility.
Which optical parameters should be selected?
TIRF, silicone-oil, plan-apochromatic, NIR and semi-apochromatic families; TIRF 100× oil objective: NA 1.49; TIRF working distance listed: 0.09–0.16 mm. Select numerical aperture, working distance, immersion medium and contrast mode using the exact objective code; do not transfer specifications between variants.
What power supply and installation are required?
Confirm the delivered power-supply input range, frequency, plug and electrical labels for the destination. Bench space, computer requirements, alignment, installation and operator training must be agreed for the selected configuration; a universal voltage specification is not assumed.
What does the estimated price exclude?
Shipping, import duties, installation and logistics are additional. Optional optics, accessories, software licenses, engineering and integration are separate unless expressly included. The final configuration and total cost will be confirmed before processing the order.
What are the warranty and after-sales arrangements?
A fixed warranty term or local on-site service package has not been verified for this supply route. The written offer must state coverage, parts and labor, remote support, repair location and responsibility for return freight.
What is the lead time and is stock available?
Current stock, production time and delivery date require confirmation for the chosen configuration, quantity and destination. No fixed dispatch or delivery promise is made in this listing.
Reviews (0)
Only logged in customers who have purchased this product may leave a review.










Reviews
There are no reviews yet.