Panall 8000 All-In-One Molecular Diagnosis System–Open System
Available in stock
Scientific China
StorePeople Also Viewed
-
SSP-GL01A Automated NGS Library Prep System
-
Automated Nucleic Acid Extraction Workstation SAW-96
-
Automated Nucleic Acid Extraction Workstation SAW-48
-
STC-96A Real-Time PCR System
-
STC-96A PLUS Real-Time PCR System
-
Nucleic Acid Extraction System SSNP-9600A
-
Nucleic Acid Extraction System SSNP-3000A
-
Nucleic Acid Extraction System SMPE-960
-
Nucleic Acid Extraction System SSNP-A6
-
Nucleic Acid Extraction System SSNP-2000B
| Manufacturer | Tianlong |
|---|---|
| Model | Open System Panall 8000 |
| Sample Throughput | 1~8 samples at the same time |
| Certificate | CE; CB; RoHS |
| Pipetting Range | 20μL ~250μL |
| Detection Time | 1~2 hours, relying on the reagent |
| Channel and Available Fluorescein | Channel 1: FAM, SYBR Green I, etc. Channel 2: VIC, HEX, TET, JOE, etc. Channel 3: ROX, Texas Red, etc. Channel 4: Cy5, etc. |
| Dimension | 750mm(L) × 350mm (W) × 600mm (H) |
| Weight | 80Kg |
| Pipetting Performance | 20μL≤V<40 μ L: accuracy:A ≤ 5.0%, repeatability:CV ≤ 3.0% 40 μ L≤V<100 μ L: accuracy: A ≤ 3.0%, repeatability: CV ≤ 1.5% V≥100 μ L: accuracy:A ≤ 1.0%, repeatability:CV ≤ 1.0% |
| Extraction Heating Rate | Average heating rate: ≥ 1.5℃/s |
| Extraction Temperature Accuracy | ≤1.0℃ |
| PCR Heating Rate | Average heating rate: ≥ 4.5℃/s Maximum heating rate: ≥ 6.1℃/s |
| PCR Cooling Rate | Average cooling rate: ≥ 3.5℃/s Maximum cooling rate: ≥ 5.0℃/s |
| PCR Temperature Accuracy | ≤0.1% |
| Sample Testing Linearity and Repeatabilit | Linear correlation: /r/≥ 0.998 Repeatability: CV ≤1.5% |
| Information Management | Sample information: with scanner inside Panall 8000 can scan and record the sample information Reagent information: visual system can automatically identify the kit information and run the corresponding program |
| Minimized Contamination | Directional exhaust & negative pressure system HEPA fltration UV disinfection Shortest fixed path for sample operation |
| Data Storage | 1000 experiment files can be stored |
| Language | Chinese and English |
| Power Supply and Power Consumption | AC 100~240V,50/60Hz:1200VA |
| Communication Specification | Internet Port: TCP/lP protocol, Ethernet connection /// USB Port: USB 2.0 |
Product Enquiry
Description
Panall 8000 All-In-One Molecular Diagnosis System–Open System
Tianlong Panall 8000 is an open system that enables laboratories to program user-defined PCR analysis protocols. Laboratories can use user-defined protocols in addition to those developed by Tianlong. The simple and efficient design of the Tianlong Panall 8000 allows you to test a wide range of sample types and meet emerging diagnostic requirements through customized reagents. Tianlong intends to work with our partners to bring more new tests to the Panall 8000 for detection of a broad range of disease categories.
Why choose the Panall 8000 All-In-One Molecular Diagnosis System–Open System?
- Compatible with PCR reagents from different manufacturers Empty PCR tubes work with your PCR reagents Customize collaboration mode for a more diversified menu Tianlong will collaborate with our partners to jointly expand the testing menu. Tianlong can customize nucleic acid extraction reagents to match your PCR reagents for more business possibilities. Available for more application scenarios An open system with a diversified testing menu can meet your emerging diagnostic reguirements and apply in more scenarios. Tianlong Panall 8000 compatible with your reagents can optimize the detection process with minimal hands-on time and make detection more efficient
Technical specifications
| Model | Open System Panall 8000 |
|---|---|
| Sample Throughput | 1~8 samples at the same time |
| Certificate | CE; CB; RoHS |
| Pipetting Range | 20μL ~250μL |
| Detection Time | 1~2 hours,relying on the reagent |
| Channel and Available Fluorescein | Channel 1: FAM, SYBR Green I, etc. Channel 2: VIC, HEX, TET, JOE, etc. Channel 3: ROX, Texas Red, etc. Channel 4: Cy5, etc. |
| Dimension | 750mm(L) × 350mm (W) × 600mm (H) |
| Weight | 80Kg |
| Pipetting Performance | 20μL≤V<40 μ L: accuracy:A ≤ 5.0%,repeatability:CV ≤ 3.0% 40 μ L≤V<100 μ L: accuracy: A ≤ 3.0%,repeatability: CV ≤ 1.5% V≥100 μ L: accuracy:A ≤ 1.0%,repeatability:CV ≤ 1.0% |
| Extraction Heating Rate | Average heating rate: ≥ 1.5℃/s |
| Extraction Temperature Accuracy | ≤1.0℃ |
| PCR Heating Rate | Average heating rate: ≥ 4.5℃/s Maximum heating rate: ≥ 6.1℃/s |
| PCR Cooling Rate | Average cooling rate: ≥ 3.5℃/s Maximum cooling rate: ≥ 5.0℃/s |
| PCR Temperature Accuracy | ≤0.1% |
| Sample Testing Linearity and Repeatabilit | Linear correlation: /r/≥ 0.998 Repeatability: CV ≤1.5% |
| Information Management | Sample information: with scanner inside Panall 8000 can scan and record the sample information Reagent information: visual system can automatically identify the kit information and run the corresponding program |
| Minimized Contamination | Directional exhaust & negative pressure system HEPA fltration UV disinfection Shortest fixed path for sample operation |
| Data Storage | 1000 experiment files can be stored |
| Language | Chinese and English |
| Power Supply and Power Consumption | AC 100~240V,50/60Hz:1200VA |
| Communication Specification | Internet Port: TCP/lP protocol, Ethernet connection /// USB Port: USB 2.0 |
Applications
Suitable for professional laboratories, hospitals, diagnostic centers, research facilities, and other qualified users requiring diagnostic & laboratory instruments.
Request a quotation
Product video
Contact Scientific China for configuration guidance, availability, minimum order quantity, shipping options, and a formal quotation.
Brand: Tianlong
Reviews (0)
Only logged in customers who have purchased this product may leave a review.














Reviews
There are no reviews yet.