Shipping Countries: United States (US)
Drawell ICP700T Inductively Coupled Plasma Emission Spectrometer
Available in stock
The Drawell ICP700T Inductively Coupled Plasma Emission Spectrometer is a professional analytical laboratory instrument. Review features and technical specifications, then request configuration, MOQ, lead time, warranty, and a formal quotation.
Scientific China
StorePeople Also Viewed
| Product Category | Spectrophotometer > ICP Emission Spectrometer(ICP-OES/AES) |
|---|
Product Enquiry
Description
Drawell ICP700T Inductively Coupled Plasma Emission Spectrometer
Product overview
ICP700T Inductively Coupled Plasma Emission Spectrometer is a trace element composition analysis and testing instrument. Mainly used in rare earth industry, silicon industry, ore analysis, metal smelting, geological research, drug safety, experimental research, environmental testing and other fields.
The Drawell ICP700T Inductively Coupled Plasma Emission Spectrometer supports research, pharmaceutical, environmental, food, industrial, and quality-control laboratories. Scientific China provides model selection, configuration review, export coordination, and formal quotations.
Key features
- 1. 70+ Elements Testing
- Covers all metals and most non-metallic elements.
- 2. Simultaneous Analysis
- Measures and reports all elements in one run.
- 3. 5–10 Elements/Min
- Standard speed of 5 elements/min, expandable to 10.
- 4. ppb-Level Detection
- Low detection limits for most elements in solution.
- 5. 5–6 Orders Linear Range
- Measures high and low concentrations simultaneously.
- 6. Minimal Chemical Interference
- Real-time background correction improves accuracy.
- It has the function of qualitative, semi-quantitative and quantitativeanalysis, and has the function of instrument diagnosis optimization. Report format the output format can be pdf, excel, electronic file, or print, and can be a Chinese template or an English template. Supports Windows.
- By optimizing the software algorithm, a real-time matrix subtraction method can be realized, and the two-dimensional coordinates can be zoomed in and out in real time for spectra with interference.
Applications
- 1. Environmental Monitoring: Detects heavy metal pollutants such as Pb, Cd, Cr, and arsenic in surface water, groundwater, soil, and solid waste for pollution control assessment and ecological environment monitoring.
- 2. Geology and Metallurgy: Analyzes the elemental composition of ores, alloys, and metallic materials, such as Cr, Ni, and Mo in steel samples, for geological exploration research and to guide production processes.
- 3. Industrial Manufacturing: Performs quality control on raw materials and products in the rare earth industry, silicon industry, electronics/electrical industry, and building materials industry, detecting the content of up to 70 elements.
Technical specifications
| Main technical parameters | |
|---|---|
| Observation system | desktop, plasma vertical observation system |
| Precision | 2ppm mixed multi-element solution, RSD≤ 1.5% |
| Stability | 2 hours RSD < 2.0% |
| The detection limit meets the A-level requirements of the national standard | |
| Flame adjustment | The plasma flame can be adjusted in three dimensions: front, back, up, down, left, and right (controlled by a computer |
| Injection system | |
| Torch tube | integrated integrated integrated quartz torch tube |
| Atomizer | Efficient concentric nebulizer, injection speed 2ml/min |
| Atomization chamber | Patented extended atomization chamber, optional with swirl atomization chamber and hydrofuoric acid resistant atomization chamber. |
| Split sampling system for real-time observation of sample injection status | |
| The mass flow controller controls the argon flow rate, which is continuously adjustable and provides real-time numerical feedback | |
| Peristaltic pump fully automatic five channel sixteen roller shaft, continuously adjustable speed | |
| RF generator and plasma | |
| Frequency | 27.12MHz Frequency stability ≤ 0.0 1% |
| Type | Solid state high-frequency RF generator, fast water cooling, automatic tuning |
| Power | 500W~1600W, continuously adjustable, with an adjustment accuracy of< l W, power stability: < 0.01% |
| Using 99.99% argon gas | |
| Equipped with reverse power protection function for RF power supply | |
| The ignition of plasma is fully automatic control | |
| Optical system | |
| Optical stability | designed on the same platform as the injection system |
| System type | Cheney Turner type (C-T type), focal length 1000mm |
| Constant temperature of the optical system, temperature stability | ±O.1°C |
| Minimum step distance of scanning motor | < 0.0004nm |
| Resolution ratio(Mn257.610nm) | <0.005nm(4320line grating);<0.008nm(3600line grating);<0.015nm(2400line grating); |
| Wavelength range | 190-460nm(4320line grating);190-500nm(3600line grating);190-800nm(2400line grating); |
| The best testing conditions for different elements can be set |
| N umber | Item name | Q uantity | Unit | Remark | C onfirm |
|---|---|---|---|---|---|
| Host | |||||
| 1.1 | ICP 700T Host | 1 | pc | ||
| software | |||||
| 2.1 | ICP Spectrometer analysis software pieces | 1 | set | Lifetime free upgrades | |
| 2.2 | Product quality certificate | 1 | set | English | |
| 2.3 | U plate | 1 | pc | ||
| 2.4 | Warranty card | 1 | pc | ||
| Accessories | |||||
| 3.1 | Network cable | 1 | pc | Category 5 twisted pair 3 rice | |
| 3.2 | plastic bucket | 1 | pcs | volume 5L | |
| 3.3 | Argon pressure reducing valve | 2 | pcs | Jierui RHM 152 IN -40 | |
| 3.4 | PU hose | 30 | meter | 10×6.5×1.75 mm | |
| 3.5 | PU hose | 5 | meter | 6×4×1 mm | |
| 3.6 | PVC Transparent hose | 0.5 | meter | 8 mm ×6 mm Transparent hose | |
| 3.7 | Plug power cord | 1 | pc | 10A, 250V | |
| 3.8 | Grounding copper braided wire | 15 | meter | Cross-sectional area 4 mm 2 | |
| 3.9 | brass tube | 1 | pc | long 500 mm , outer diameter 48 mm , wall thickness 3 mm | |
| 3.10 | filter cartridges | 4 | pcs | Outer diameter: 60 mm , inner diameter: 28 mm , length :125 mm | |
| 3.11 | Torch | 2 | pcs | Quartz torch | |
| 3.12 | Double-tube spray chamber | 2 | pcs | Scott Spray chamber | |
| 3.13 | atomizer | 1 | pc | Imported atomizer | |
| 3.14 | High-frequency coil | 1 | pc | ||
| 3.15 | Capillary injection tube | 0.5 | meter | D=2.38 mm , d=0.8 mm | |
| 3.16 | Peristaltic pump head hose | 3 | pcs | Ф 1.65, long 45 cm , two cards | |
| 3.17 | Cartridge fuse | 2 | pcs | 10A, 250V, 6×30 mm | |
| 3.18 | Cartridge fuse | 2 | pcs | 6.3A, 250V, 5×20 mm | |
| 3.19 | Cylindrical spray chamber cover | 2 | pcs | polytetrafluoroethylene | |
| 3.20 | Silicone tube | 2 | meter | inner diameter 2 mm , outer diameter 4 mm , hardness 55 | |
| 3.21 | Hose adapter | 4 | pcs | ZCJH -2*6 Straight through, inner diameter 6-2 | |
| 3.22 | Hose adapter | 4 | pcs | ZC -1/16*3/32, inner diameter 1.6-2.4 | |
| 3.23 | Ball joint clamp | 1 | pc | L00091181,Ø=10 |
| No. | Name | Specification | Replacement cycle |
|---|---|---|---|
| 1 | Torch | Quartz torch | Clean and maintain once every 3 months.Service life 2 years |
| 2 | Nebulizer | Import GE nebulizer | Non-human damage over 3 years |
| 3 | Spray chamber | Double-tube spray chamber | Non-human damage over 3 years |
| 4 | Peristaltic Pump Head Hose | Injection and Drain Tubing | 3 Months |
| 5 | High- frequency coil | Silver-plated, three-turn coil | One year |
| 6 | Filter element | PP cotton material | Half a year |
Ordering and configuration
Final specifications, included accessories, consumables, software, certifications, power requirements, installation, warranty, and regulatory availability depend on the selected model and destination. Contact Scientific China to confirm the suitable configuration, minimum order quantity, price, lead time, documentation, and international delivery terms before purchase.
Reviews (0)
Only logged in customers who have purchased this product may leave a review.